Measurement of water vapor line strengths in the 1.4–2.7 µm range by tunable diode laser absorption spectroscopy. (November 2015)
- Record Type:
- Journal Article
- Title:
- Measurement of water vapor line strengths in the 1.4–2.7 µm range by tunable diode laser absorption spectroscopy. (November 2015)
- Main Title:
- Measurement of water vapor line strengths in the 1.4–2.7 µm range by tunable diode laser absorption spectroscopy
- Authors:
- Pogány, Andrea
Klein, Alexander
Ebert, Volker - Abstract:
- Abstract: Line strengths of nine water vapor absorption lines in the wavelength range between 1.37 and 2.71 µm with line strengths of 10 –23 –10 –20 cm/molecule have been measured using direct tunable diode laser absorption spectroscopy (dTDLAS). Four different light sources were used: three distributed feedback (DFB) diode lasers with wavelengths of 1.37 µm, 2.55 µm and 2.71 µm for measuring one application-specifically selected absorption line with each laser, and a vertical-cavity surface-emitting laser (VCSEL) radiating around 1.39 µm for the measurement of six further absorption lines. Despite the different light sources and line strengths, a uniform measurement and data evaluation method was developed and applied to all lines, and the experimental set-up was kept as similar as possible. This allows a thorough and uniform uncertainty analysis and evaluation of the contributions of the individual experimental parameters to the uncertainty of the derived line strengths. A comprehensive and transparent uncertainty analysis is given for the measurements. Uncertainties of our measured line strengths are in the 1.1–2.5% range ( k =2, 95% confidence level). Our measured line strength values agree well with line strengths in the HITRAN 2012 database and other literature sources, we realized lower uncertainties up to a factor of 5–10. Highlights: Accurate line strength measurement of nine NIR water vapor lines. dTDLAS set-up using a single pass cell and different diode lasersAbstract: Line strengths of nine water vapor absorption lines in the wavelength range between 1.37 and 2.71 µm with line strengths of 10 –23 –10 –20 cm/molecule have been measured using direct tunable diode laser absorption spectroscopy (dTDLAS). Four different light sources were used: three distributed feedback (DFB) diode lasers with wavelengths of 1.37 µm, 2.55 µm and 2.71 µm for measuring one application-specifically selected absorption line with each laser, and a vertical-cavity surface-emitting laser (VCSEL) radiating around 1.39 µm for the measurement of six further absorption lines. Despite the different light sources and line strengths, a uniform measurement and data evaluation method was developed and applied to all lines, and the experimental set-up was kept as similar as possible. This allows a thorough and uniform uncertainty analysis and evaluation of the contributions of the individual experimental parameters to the uncertainty of the derived line strengths. A comprehensive and transparent uncertainty analysis is given for the measurements. Uncertainties of our measured line strengths are in the 1.1–2.5% range ( k =2, 95% confidence level). Our measured line strength values agree well with line strengths in the HITRAN 2012 database and other literature sources, we realized lower uncertainties up to a factor of 5–10. Highlights: Accurate line strength measurement of nine NIR water vapor lines. dTDLAS set-up using a single pass cell and different diode lasers (DFB and VCSEL). Detailed uncertainty assessment, combined expanded uncertainty of 1.1–2.5% (95% conf. interval). Results compare well to literature values, but show lower uncertainty. … (more)
- Is Part Of:
- Journal of quantitative spectroscopy & radiative transfer. Volume 165(2016:Mar.)
- Journal:
- Journal of quantitative spectroscopy & radiative transfer
- Issue:
- Volume 165(2016:Mar.)
- Issue Display:
- Volume 165 (2016)
- Year:
- 2016
- Volume:
- 165
- Issue Sort Value:
- 2016-0165-0000-0000
- Page Start:
- 108
- Page End:
- 122
- Publication Date:
- 2015-11
- Subjects:
- Line strength -- Water vapor -- Tunable diode laser absorption spectroscopy -- Uncertainty, Metrology
Spectrum analysis -- Periodicals
Radiation -- Periodicals
Analyse spectrale -- Périodiques
Rayonnement -- Périodiques
Radiation
Spectrum analysis
Periodicals
543.0858 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00224073 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jqsrt.2015.06.023 ↗
- Languages:
- English
- ISSNs:
- 0022-4073
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5043.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21403.xml