Primary results from the Japanese Heart Failure and Sudden Cardiac Death Prevention Trial (HINODE). (1st April 2022)
- Record Type:
- Journal Article
- Title:
- Primary results from the Japanese Heart Failure and Sudden Cardiac Death Prevention Trial (HINODE). (1st April 2022)
- Main Title:
- Primary results from the Japanese Heart Failure and Sudden Cardiac Death Prevention Trial (HINODE)
- Authors:
- Aonuma, Kazutaka
Ando, Kenji
Kusano, Kengo
Asai, Toru
Inoue, Koichi
Inamura, Yukihiro
Ikeda, Takanori
Mitsuhashi, Takeshi
Murohara, Toyoaki
Nishii, Nobuhiro
Nogami, Akihiko
Shimizu, Wataru
Beaudoint, Caroline
Simon, Torri
Kayser, Torsten
Azlan, Hussin
Tachapong, Ngarmukos
Chan, Joseph Yat‐Sun
Kutyifa, Valentina
Sakata, Yasushi - Abstract:
- Abstract: Aims: The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular arrhythmias (VA), and heart failure in Japanese patients and compared with those in Western patients. Methods and results: After treatment decisions following contemporary practice in Japan, patients were prospectively enrolled into four cohorts: (i) internal cardioverter‐defibrillator (ICD), (ii) cardiac resynchronization therapy (CRT) defibrillator (CRT‐D), (iii) standard medical therapy ('non‐device': ND), or (iv) pacing (indicated for CRT; received pacemaker or CRT pacing). Cohorts 1–3 required a left ventricular ejection fraction ≤35%, a history of heart failure, and a need for primary prevention of sudden cardiac death based on two to five previously identified risk factors. Endpoint outcomes were adjudicated by the independent committees. ICD and CRT‐D cohorts, considered as high‐voltage (HV) cohorts, were pooled for Kaplan–Meier analysis and propensity‐matched to Multicenter Automatic Defibrillator Implantation Trial‐Reduce Inappropriate Therapy (MADIT‐RIT) arm B and C patients. The study enrolled 354 patients followed for 19.6 ± 6.5 months, with a minimum of 12 months. Propensity‐matched HV cohorts showed comparable VA ( P = 0.61) and mortality rates ( P = 0.29) for HINODE and MADIT‐RIT. The ND cohort presented a high crossover rate to ICD therapy (6.1%, n = 7/115), and the CRT‐D cohort showed elevated mortality rates. The pacing cohort revealed that patientsAbstract: Aims: The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular arrhythmias (VA), and heart failure in Japanese patients and compared with those in Western patients. Methods and results: After treatment decisions following contemporary practice in Japan, patients were prospectively enrolled into four cohorts: (i) internal cardioverter‐defibrillator (ICD), (ii) cardiac resynchronization therapy (CRT) defibrillator (CRT‐D), (iii) standard medical therapy ('non‐device': ND), or (iv) pacing (indicated for CRT; received pacemaker or CRT pacing). Cohorts 1–3 required a left ventricular ejection fraction ≤35%, a history of heart failure, and a need for primary prevention of sudden cardiac death based on two to five previously identified risk factors. Endpoint outcomes were adjudicated by the independent committees. ICD and CRT‐D cohorts, considered as high‐voltage (HV) cohorts, were pooled for Kaplan–Meier analysis and propensity‐matched to Multicenter Automatic Defibrillator Implantation Trial‐Reduce Inappropriate Therapy (MADIT‐RIT) arm B and C patients. The study enrolled 354 patients followed for 19.6 ± 6.5 months, with a minimum of 12 months. Propensity‐matched HV cohorts showed comparable VA ( P = 0.61) and mortality rates ( P = 0.29) for HINODE and MADIT‐RIT. The ND cohort presented a high crossover rate to ICD therapy (6.1%, n = 7/115), and the CRT‐D cohort showed elevated mortality rates. The pacing cohort revealed that patients implanted with pacemakers had higher mortality (26.0%) than those with CRT‐Pacing (8.4%, P = 0.05). Conclusions: The mortality and VA event rates of landmark trials are applicable to patients with primary prevention in Japan. Patients who did not receive guideline‐indicated CRT devices had poor outcomes. … (more)
- Is Part Of:
- ESC heart failure. Volume 9:Number 3(2022)
- Journal:
- ESC heart failure
- Issue:
- Volume 9:Number 3(2022)
- Issue Display:
- Volume 9, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 9
- Issue:
- 3
- Issue Sort Value:
- 2022-0009-0003-0000
- Page Start:
- 1584
- Page End:
- 1596
- Publication Date:
- 2022-04-01
- Subjects:
- Defibrillator therapy -- Ventricular arrhythmia -- Sudden cardiac death -- Japan, primary prevention -- Electrophysiologic studies
Heart failure -- Periodicals
616.129005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2055-5822 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ehf2.13901 ↗
- Languages:
- English
- ISSNs:
- 2055-5822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21348.xml