Sensitive pH-responsive point-of-care electrochemical immunoassay for influenza A (H1N1) virus using glucose oxidase-functionalized Ti3C2–MXene nanosheets. Issue 13 (16th June 2021)
- Record Type:
- Journal Article
- Title:
- Sensitive pH-responsive point-of-care electrochemical immunoassay for influenza A (H1N1) virus using glucose oxidase-functionalized Ti3C2–MXene nanosheets. Issue 13 (16th June 2021)
- Main Title:
- Sensitive pH-responsive point-of-care electrochemical immunoassay for influenza A (H1N1) virus using glucose oxidase-functionalized Ti3C2–MXene nanosheets
- Authors:
- Lin, Shuwen
Hu, Xiaomei
Lin, Jiayi
Wang, Shunqin
Xu, Jin
Cai, Fan
Lin, Jiancheng - Abstract:
- Abstract : A pH-responsive electrochemical immunoassay was designed to monitor H1N1 influenza virus using glucose oxidase and antibody-functionalized Ti3 C2 –MXene nanosheets. Abstract : Influenza A (H1N1) virus is a serious health threat and potential leading cause of death around the world during the processes of immunity and inflammation. Herein a sensitive pH-responsive point-of-care (POC) electrochemical immunoassay was designed for the quantitative monitoring of H1N1 influenza virus using glucose oxidase (GOx) and secondary antibody-functionalized Ti3 C2 –MXene nanosheets. The assay was carried out on the basis of the sandwich-type immunoreaction in the capture antibody-coated microplate. Two-dimensional (2D) Ti3 C2 –MXene nanosheets with a large surface area could efficiently enhance the loading amount of GOx molecules, thereby resulting in the signal amplification. Accompanying the formed immunocomplexes, labeled GOx molecules catalyzed glucose into gluconic acid and hydrogen peroxide. The generated gluconic acid caused a pH change of the detection solution, which was quantitatively determined on a handheld pH meter. Two labeling strategies with and without Ti3 C2 –MXene nanosheets were investigated to determine the target H1N1 influenza virus, and improved properties were acquired with the Ti3 C2 –MXene-labeled system. Under optimum conditions, the Ti3 C2 –MXene-based immunoassay gave good dynamic responses toward the target H1N1 influenza virus from 0.01 μg mL −1Abstract : A pH-responsive electrochemical immunoassay was designed to monitor H1N1 influenza virus using glucose oxidase and antibody-functionalized Ti3 C2 –MXene nanosheets. Abstract : Influenza A (H1N1) virus is a serious health threat and potential leading cause of death around the world during the processes of immunity and inflammation. Herein a sensitive pH-responsive point-of-care (POC) electrochemical immunoassay was designed for the quantitative monitoring of H1N1 influenza virus using glucose oxidase (GOx) and secondary antibody-functionalized Ti3 C2 –MXene nanosheets. The assay was carried out on the basis of the sandwich-type immunoreaction in the capture antibody-coated microplate. Two-dimensional (2D) Ti3 C2 –MXene nanosheets with a large surface area could efficiently enhance the loading amount of GOx molecules, thereby resulting in the signal amplification. Accompanying the formed immunocomplexes, labeled GOx molecules catalyzed glucose into gluconic acid and hydrogen peroxide. The generated gluconic acid caused a pH change of the detection solution, which was quantitatively determined on a handheld pH meter. Two labeling strategies with and without Ti3 C2 –MXene nanosheets were investigated to determine the target H1N1 influenza virus, and improved properties were acquired with the Ti3 C2 –MXene-labeled system. Under optimum conditions, the Ti3 C2 –MXene-based immunoassay gave good dynamic responses toward the target H1N1 influenza virus from 0.01 μg mL −1 to 100 μg mL −1 with a detection limit of 1.3 ng mL −1 . Good reproducibility, high specificity, and acceptable stability were also achieved in the analysis of the target H1N1 influenza virus. Significantly, measurements of the H1N1 influenza virus from clinical human samples were demonstrated to further confirm the method reliability and accuracy of the Ti3 C2 –MXene-based electrochemical immunoassay. Importantly, such a pH-meter-based immunoassay can be suitable for use in point-of-care applications and opens new opportunities for diagnostics. … (more)
- Is Part Of:
- Analyst. Volume 146:Issue 13(2021)
- Journal:
- Analyst
- Issue:
- Volume 146:Issue 13(2021)
- Issue Display:
- Volume 146, Issue 13 (2021)
- Year:
- 2021
- Volume:
- 146
- Issue:
- 13
- Issue Sort Value:
- 2021-0146-0013-0000
- Page Start:
- 4391
- Page End:
- 4399
- Publication Date:
- 2021-06-16
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1an00606a ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21346.xml