Fabrication of Co3O4 quantum dot incorporated polyacrylamide ethylene glycol dimethacrylate as a new fiber for solid phase microextraction and trace determination of organophosphorus pesticides in environmental water samples. Issue 30 (8th July 2021)
- Record Type:
- Journal Article
- Title:
- Fabrication of Co3O4 quantum dot incorporated polyacrylamide ethylene glycol dimethacrylate as a new fiber for solid phase microextraction and trace determination of organophosphorus pesticides in environmental water samples. Issue 30 (8th July 2021)
- Main Title:
- Fabrication of Co3O4 quantum dot incorporated polyacrylamide ethylene glycol dimethacrylate as a new fiber for solid phase microextraction and trace determination of organophosphorus pesticides in environmental water samples
- Authors:
- Aladaghlo, Zolfaghar
Maddah, Bozorgmehr
Fakhari, Ali Reza - Abstract:
- Abstract : A solid phase microextraction fiber based on Co3 O4 quantum dot incorporated polyacrylamide-co-ethylene glycol dimethacrylate followed by corona discharge ion mobility spectrometry is shown for trace determination of organophosphorus pesticides in environmental water samples. Abstract : In this paper, a novel solid phase microextraction fiber based on Co3 O4 quantum dot incorporated polyacrylamide- co -ethylene glycol dimethacrylate followed by corona discharge ion mobility spectrometry is presented for the trace determination of organophosphorus pesticides in environmental water samples. Ion mobility spectrometry is a comparatively inexpensive, well-known, robust, and easy to operate analytical instrument. This combination would provide a low-cost, fast, selective, and sensitive quantitative system for detection of organophosphorus pesticides. In order to obtain the best extraction efficiency, the optimization of parameters affecting this method was carried out. After optimization, a solution pH of 7.0, extraction temperature of 60 °C, adsorption temperature of 260 °C, extraction time of 30 min, stirring speed of 750 rpm, and ionic strength of 10% w/w were obtained. Consequently, the presented method showed low limits of detection (0.3–0.6 ng mL −1 ), excellent enrichment factors (PF = 221–263), good linearity ( R 2 > 0.995), and repeatabilities (intra-day: 3.4 to 4.8%) and (inter-day: 4.7 to 6.1%). The reproducibility (RSD% of fiber to fiber) was alsoAbstract : A solid phase microextraction fiber based on Co3 O4 quantum dot incorporated polyacrylamide-co-ethylene glycol dimethacrylate followed by corona discharge ion mobility spectrometry is shown for trace determination of organophosphorus pesticides in environmental water samples. Abstract : In this paper, a novel solid phase microextraction fiber based on Co3 O4 quantum dot incorporated polyacrylamide- co -ethylene glycol dimethacrylate followed by corona discharge ion mobility spectrometry is presented for the trace determination of organophosphorus pesticides in environmental water samples. Ion mobility spectrometry is a comparatively inexpensive, well-known, robust, and easy to operate analytical instrument. This combination would provide a low-cost, fast, selective, and sensitive quantitative system for detection of organophosphorus pesticides. In order to obtain the best extraction efficiency, the optimization of parameters affecting this method was carried out. After optimization, a solution pH of 7.0, extraction temperature of 60 °C, adsorption temperature of 260 °C, extraction time of 30 min, stirring speed of 750 rpm, and ionic strength of 10% w/w were obtained. Consequently, the presented method showed low limits of detection (0.3–0.6 ng mL −1 ), excellent enrichment factors (PF = 221–263), good linearity ( R 2 > 0.995), and repeatabilities (intra-day: 3.4 to 4.8%) and (inter-day: 4.7 to 6.1%). The reproducibility (RSD% of fiber to fiber) was also investigated by analyzing three as-prepared fibers under the same conditions and was found to be less than 7.6%. Finally, the developed fiber was used for determination of organophosphorus pesticides in the field samples. … (more)
- Is Part Of:
- Analytical methods. Volume 13:Issue 30(2021)
- Journal:
- Analytical methods
- Issue:
- Volume 13:Issue 30(2021)
- Issue Display:
- Volume 13, Issue 30 (2021)
- Year:
- 2021
- Volume:
- 13
- Issue:
- 30
- Issue Sort Value:
- 2021-0013-0030-0000
- Page Start:
- 3394
- Page End:
- 3401
- Publication Date:
- 2021-07-08
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1ay00855b ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21333.xml