A new method for broadening the detection range of immunoassay and its application in β-hCG quantitative detection. Issue 15 (29th March 2022)
- Record Type:
- Journal Article
- Title:
- A new method for broadening the detection range of immunoassay and its application in β-hCG quantitative detection. Issue 15 (29th March 2022)
- Main Title:
- A new method for broadening the detection range of immunoassay and its application in β-hCG quantitative detection
- Authors:
- Zhang, Bei
Guo, Miao
Zhang, Tianjie
Liu, Dandan
Tan, Xin
Li, Xue
Yu, Yang
Li, Huiqiang - Abstract:
- Abstract : The combination of two solid-phase monoclonal antibodies with different affinities allows the antibodies to act selectively according to the concentration of β-hCG in the sample, thus ensuring sensitivity and broadening the detection range. Abstract : Early pregnancy prediction requires very high β-hCG detection sensitivity, while embryonic development monitoring and trophoblastic disease detection require a wider detection range. In this study, based on light-initiated chemiluminescence assay (LICA), one high-affinity mAb and one low-affinity mAb were selected and coated on chemibeads with a larger coating area in different ratios to immobilize the antibodies. The two immobilized mAbs were mixed with different concentrations to detect β-hCG. When the high-affinity mAb-coated chemibeads and low-affinity mAb-coated chemibeads were used at working concentrations of 0.100 mg mL −1 and 0.014 mg mL −1, respectively, the sensitivity and detection range were maximized. The assay was precise for measuring β-hCG with repeatability and intermediate precision of <5% CV. The assay has a high sensitivity with a limit of quantification (LoQ) of 0.49 IU L −1, which is lower than that of most β-hCG detection kits. Over the range of 1 IU L −1 to 16 000 IU L −1, the assay had a proper linearity ( r = 0.9995). No false negative results due to the hook effect were observed at β-hCG concentrations up to 225 000 IU L −1 . The assay showed a good correlation with the Abbott assay ( r =Abstract : The combination of two solid-phase monoclonal antibodies with different affinities allows the antibodies to act selectively according to the concentration of β-hCG in the sample, thus ensuring sensitivity and broadening the detection range. Abstract : Early pregnancy prediction requires very high β-hCG detection sensitivity, while embryonic development monitoring and trophoblastic disease detection require a wider detection range. In this study, based on light-initiated chemiluminescence assay (LICA), one high-affinity mAb and one low-affinity mAb were selected and coated on chemibeads with a larger coating area in different ratios to immobilize the antibodies. The two immobilized mAbs were mixed with different concentrations to detect β-hCG. When the high-affinity mAb-coated chemibeads and low-affinity mAb-coated chemibeads were used at working concentrations of 0.100 mg mL −1 and 0.014 mg mL −1, respectively, the sensitivity and detection range were maximized. The assay was precise for measuring β-hCG with repeatability and intermediate precision of <5% CV. The assay has a high sensitivity with a limit of quantification (LoQ) of 0.49 IU L −1, which is lower than that of most β-hCG detection kits. Over the range of 1 IU L −1 to 16 000 IU L −1, the assay had a proper linearity ( r = 0.9995). No false negative results due to the hook effect were observed at β-hCG concentrations up to 225 000 IU L −1 . The assay showed a good correlation with the Abbott assay ( r = 0.9910). LICA combined with immobilized mAbs with different affinities ensures the sensitivity of β-hCG detection and broadens the detection range. … (more)
- Is Part Of:
- Analytical methods. Volume 14:Issue 15(2022)
- Journal:
- Analytical methods
- Issue:
- Volume 14:Issue 15(2022)
- Issue Display:
- Volume 14, Issue 15 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 15
- Issue Sort Value:
- 2022-0014-0015-0000
- Page Start:
- 1515
- Page End:
- 1522
- Publication Date:
- 2022-03-29
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ay00220e ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21402.xml