Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device. (16th February 2022)
- Record Type:
- Journal Article
- Title:
- Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device. (16th February 2022)
- Main Title:
- Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device
- Authors:
- Sayer, Gabriel
Piper, Greta
Vorovich, Esther
Raikhelkar, Jayant
Kim, Gene H
Rodgers, Daniel
Shimbo, Daichi
Uriel, Nir - Abstract:
- Abstract: BACKGROUND: Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS: We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS: Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 ± 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 ± 6.9 mm Hg for SBP and 1.2 ± 5.7 mm Hg for DBP. The mean absolute error was 8.2 ± 5.8 mm Hg for SBP and 6.4 ± 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS: The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offerAbstract: BACKGROUND: Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS: We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS: Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 ± 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 ± 6.9 mm Hg for SBP and 1.2 ± 5.7 mm Hg for DBP. The mean absolute error was 8.2 ± 5.8 mm Hg for SBP and 6.4 ± 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS: The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offer advantages over currently available BP monitors. CLINICAL TRIALS REGISTRATION: Trial Number NCT03919136. Graphical Abstract: … (more)
- Is Part Of:
- American journal of hypertension. Volume 35:Number 5(2022)
- Journal:
- American journal of hypertension
- Issue:
- Volume 35:Number 5(2022)
- Issue Display:
- Volume 35, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 35
- Issue:
- 5
- Issue Sort Value:
- 2022-0035-0005-0000
- Page Start:
- 407
- Page End:
- 413
- Publication Date:
- 2022-02-16
- Subjects:
- blood pressure -- blood pressure measurement/monitoring -- cardiovascular disease -- hypertension -- remote monitoring
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://ajh.oxfordjournals.org/ ↗
http://www.nature.com/ajh/index.html ↗
http://ukcatalogue.oup.com/ ↗
http://www.sciencedirect.com/science/journal/08957061 ↗ - DOI:
- 10.1093/ajh/hpac020 ↗
- Languages:
- English
- ISSNs:
- 0895-7061
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0826.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21416.xml