Impact of SMART Pass filter in patients with ajmaline-induced Brugada syndrome and subcutaneous implantable cardioverter-defibrillator eligibility failure: results from a prospective multicentre study. Issue 5 (9th September 2021)
- Record Type:
- Journal Article
- Title:
- Impact of SMART Pass filter in patients with ajmaline-induced Brugada syndrome and subcutaneous implantable cardioverter-defibrillator eligibility failure: results from a prospective multicentre study. Issue 5 (9th September 2021)
- Main Title:
- Impact of SMART Pass filter in patients with ajmaline-induced Brugada syndrome and subcutaneous implantable cardioverter-defibrillator eligibility failure: results from a prospective multicentre study
- Authors:
- Conte, Giulio
Cattaneo, Fabio
de Asmundis, Carlo
Berne, Paola
Vicentini, Alessandro
Namdar, Mehdi
Scalone, Antonio
Klersy, Catherine
Caputo, Maria Luce
Demarchi, Andrea
Özkartal, Tardu
Salghetti, Francesca
Casu, Gavino
Passarelli, Ilaria
Mameli, Stefano
Shah, Dipen
Burri, Haran
De Ferrari, Gaetano
Brugada, Pedro
Auricchio, Angelo - Abstract:
- Abstract: Aims: Ajmaline challenge can unmask subcutaneous implantable cardioverter-defibrillator (S-ICD) screening failure in patients with Brugada syndrome (BrS) and non-diagnostic baseline electrocardiogram (ECG). The efficacy of the SMART Pass (SP) filter, a high-pass filter designed to reduce cardiac oversensing (while maintaining an appropriate sensing margin), has not yet been assessed in patients with BrS. The aim of this prospective multicentre study was to investigate the effect of the SP filter on dynamic Brugada ECG changes evoked by ajmaline and to assess its value in reducing S-ICD screening failure in patients with drug-induced Brugada ECGs. Methods and results: The S-ICD screening with conventional automated screening tool (AST) was performed during ajmaline challenge in subjects with suspected BrS. The S-ICD recordings were obtained before, during and after ajmaline administration and evaluated by the means of a simulation model that emulates the AST behaviour with and without SP filter. A patient was considered suitable for S-ICD if at least one sensing vector was acceptable in all tested postures. A sensing vector was considered acceptable in the presence of QRS amplitude >0.5 mV, QRS/T-wave ratio >3.5, and sense vector score >100. Of the 126 subjects (mean age: 42 ± 14 years, males: 61%, sensing vectors: 6786), 46 (36%) presented with an ajmaline-induced Brugada type 1 ECG. Up to 30% of subjects and 40% of vectors failed the screening during theAbstract: Aims: Ajmaline challenge can unmask subcutaneous implantable cardioverter-defibrillator (S-ICD) screening failure in patients with Brugada syndrome (BrS) and non-diagnostic baseline electrocardiogram (ECG). The efficacy of the SMART Pass (SP) filter, a high-pass filter designed to reduce cardiac oversensing (while maintaining an appropriate sensing margin), has not yet been assessed in patients with BrS. The aim of this prospective multicentre study was to investigate the effect of the SP filter on dynamic Brugada ECG changes evoked by ajmaline and to assess its value in reducing S-ICD screening failure in patients with drug-induced Brugada ECGs. Methods and results: The S-ICD screening with conventional automated screening tool (AST) was performed during ajmaline challenge in subjects with suspected BrS. The S-ICD recordings were obtained before, during and after ajmaline administration and evaluated by the means of a simulation model that emulates the AST behaviour with and without SP filter. A patient was considered suitable for S-ICD if at least one sensing vector was acceptable in all tested postures. A sensing vector was considered acceptable in the presence of QRS amplitude >0.5 mV, QRS/T-wave ratio >3.5, and sense vector score >100. Of the 126 subjects (mean age: 42 ± 14 years, males: 61%, sensing vectors: 6786), 46 (36%) presented with an ajmaline-induced Brugada type 1 ECG. Up to 30% of subjects and 40% of vectors failed the screening during the appearance of Brugada type 1 ECG evoked by ajmaline. The S-ICD screening failure rate was not significantly reduced in patients with Brugada ECGs when SP filter was enabled (30% vs. 24%). Similarly, there was only a trend in reduction of vector-failure rate attributable to the SP filter (from 40% to 36%). The most frequent reason for screening failure was low QRS amplitude or low QRS/T-wave ratio. None of these patients was implanted with an S-ICD. Conclusion: Patients who pass the sensing screening during ajmaline can be considered good candidates for S-ICD implantation, while those who fail might be susceptible to sensing issues. Although there was a trend towards reduction of vector sensing failure rate when SP filter was enabled, the reduction in S-ICD screening failure in patients with Brugada ECGs did not reach statistical significance. Clinical trial registration: https://clinicaltrials.gov Unique Identifier NCT04504591. … (more)
- Is Part Of:
- Europace. Volume 24:Issue 5(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Issue 5(2022)
- Issue Display:
- Volume 24, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 5
- Issue Sort Value:
- 2022-0024-0005-0000
- Page Start:
- 845
- Page End:
- 854
- Publication Date:
- 2021-09-09
- Subjects:
- Brugada syndrome -- Subcutaneous implantable cardioverter-defibrillator -- SMART Pass -- Screening -- Eligibility -- Sudden cardiac death
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab230 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21415.xml