SEARCH FOR EXPERIMENTAL EVIDENCE OF DOSE-RATE AND WALL SCATTERING EFFECTS IN THE THERMOLUMINESCENCE RESPONSE OF LIF:MG, TI (TLD-100). Issue 4 (21st March 2022)
- Record Type:
- Journal Article
- Title:
- SEARCH FOR EXPERIMENTAL EVIDENCE OF DOSE-RATE AND WALL SCATTERING EFFECTS IN THE THERMOLUMINESCENCE RESPONSE OF LIF:MG, TI (TLD-100). Issue 4 (21st March 2022)
- Main Title:
- SEARCH FOR EXPERIMENTAL EVIDENCE OF DOSE-RATE AND WALL SCATTERING EFFECTS IN THE THERMOLUMINESCENCE RESPONSE OF LIF:MG, TI (TLD-100)
- Authors:
- Ginzburg, Dimitry
Eliyahu, Ilan
Spooner, Nigel
Sterenberg, Matan
Reshes, Galina
Shapiro, Alex
Biderman, Shlomo
Herman, Beny
Assor, Yossi
Nemirovsky, Dimitry
Oster, Leonid
Horowitz, Yigal Shalom
Hershkovich, David - Abstract:
- Abstract: An experimental investigation into the possibility of dose-rate effects and wall scatter in the thermoluminescent response of LiF:Mg, Ti (TLD-100) was carried out. The investigation was motivated by theoretical simulations predicting the possible presence of dose-rate effects coupled with the lack of detailed experimental studies. The dose rate was varied by changing the source to sample distance, by the use of attenuators, sources of 137 Cs of various activities, filtration and the construction of identical geometrical irradiators of Teflon and stainless steel. Four levels of dose in the linear dose response region were studied at 10 −2 Gy, 1.5 × 10 −2 Gy, 0.1 Gy and 0.5 Gy to avoid complications in interpretation due to supralinearity above 1 Gy. At the dose of 1.5 × 10 −2 Gy, the dose rate was varied by five orders of magnitude from 4.9 × 10 −3 Gy s −1 to 4.9 × 10 −8 Gy s −1 . At the other levels of dose, a one to two orders of magnitude in dose rate was achieved. Within the measurement uncertainty of 5–10%, no dose-rate effects were observed in any of the experimental measurements and no changes in the shape of the glow curve were observed. The maximum wall scatter effect (Teflon to stainless steel) was measured at ~8% within the experimental uncertainty and well below expectations. The results are encouraging with respect to the accurate and reproducible use of LiF:Mg, Ti under various experimental conditions of irradiation.
- Is Part Of:
- Radiation protection dosimetry. Volume 198:Issue 4(2022)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 198:Issue 4(2022)
- Issue Display:
- Volume 198, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 198
- Issue:
- 4
- Issue Sort Value:
- 2022-0198-0004-0000
- Page Start:
- 222
- Page End:
- 228
- Publication Date:
- 2022-03-21
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncac029 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21339.xml