Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial. Issue 3 (March 2022)
- Main Title:
- Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
- Authors:
- Chang, Daniel H.
Janakiraman, Devi Priya
Smith, Pamela J.
Buteyn, Anne
Domingo, Joy
Jones, Jason J.
Christie, William C. - Abstract:
- Abstract : Randomized comparison of the TECNIS Symfony (ZXR00) and the TECNIS 1-piece monofocal (ZCB00) intraocular lenses in cataract surgery demonstrates improved intermediate and near vision with TECNIS Symfony. Abstract : Purpose: To compare the effectiveness and safety of the TECNIS Symfony intraocular lens (IOL; ZXR00) with the TECNIS 1-piece monofocal IOL (ZCB00). Setting: 15 sites in the United States. Design: Prospective, randomized, patient-masked/evaluator-masked clinical trial. Methods: Randomized participants received either the ZXR00 or ZCB00 IOL bilaterally. The 6-month postoperative outcomes included monocular and binocular distance, intermediate, and near visual acuity (VA), spherical equivalent refraction and refractive cylinder, spectacle wear, and visual symptoms. Results: Overall, 299 patients were implanted with a study IOL (ZXR00 IOL, n = 148; ZCB00 IOL control, n = 151). At the 6-month follow-up, mean binocular uncorrected distance VA was comparable between ZXR00 and ZCB00 IOL recipients ( P = .1011). The ZXR00 IOL group had significantly better mean binocular uncorrected intermediate VA and uncorrected near VA (both P < .0001) than the ZCB00 IOL group. The mean binocular distance-corrected intermediate VA and distance-corrected near VA were also better in the ZXR00 IOL group (both P < .0001). More ZXR00 IOL recipients reported wearing spectacles none of the time or a little of the time for overall vision at 6 months compared with the ZCB00 IOL groupAbstract : Randomized comparison of the TECNIS Symfony (ZXR00) and the TECNIS 1-piece monofocal (ZCB00) intraocular lenses in cataract surgery demonstrates improved intermediate and near vision with TECNIS Symfony. Abstract : Purpose: To compare the effectiveness and safety of the TECNIS Symfony intraocular lens (IOL; ZXR00) with the TECNIS 1-piece monofocal IOL (ZCB00). Setting: 15 sites in the United States. Design: Prospective, randomized, patient-masked/evaluator-masked clinical trial. Methods: Randomized participants received either the ZXR00 or ZCB00 IOL bilaterally. The 6-month postoperative outcomes included monocular and binocular distance, intermediate, and near visual acuity (VA), spherical equivalent refraction and refractive cylinder, spectacle wear, and visual symptoms. Results: Overall, 299 patients were implanted with a study IOL (ZXR00 IOL, n = 148; ZCB00 IOL control, n = 151). At the 6-month follow-up, mean binocular uncorrected distance VA was comparable between ZXR00 and ZCB00 IOL recipients ( P = .1011). The ZXR00 IOL group had significantly better mean binocular uncorrected intermediate VA and uncorrected near VA (both P < .0001) than the ZCB00 IOL group. The mean binocular distance-corrected intermediate VA and distance-corrected near VA were also better in the ZXR00 IOL group (both P < .0001). More ZXR00 IOL recipients reported wearing spectacles none of the time or a little of the time for overall vision at 6 months compared with the ZCB00 IOL group (85.0% vs 59.9%, P < .0001). In the ZXR00 IOL–implanted patients, low incidence rates of night glare (mild to moderate, 2.7%), halo (mild to moderate, 13.6%; severe, 2.7%), and starbursts (mild to moderate, 7.5%; severe, 1.4%) were reported. Conclusions: The TECNIS Symfony IOL provided comparable distance vision and improved uncorrected and distance-corrected intermediate and near vision, along with decreased spectacle wear and low incidence rates of dysphotopsia, compared with the TECNIS 1-piece monofocal IOL. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 48:Issue 3(2022)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 48:Issue 3(2022)
- Issue Display:
- Volume 48, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 3
- Issue Sort Value:
- 2022-0048-0003-0000
- Page Start:
- 288
- Page End:
- 297
- Publication Date:
- 2022-03
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000747 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21320.xml