A new approach for daily life Blood-Pressure estimation using smart watch. (May 2022)
- Record Type:
- Journal Article
- Title:
- A new approach for daily life Blood-Pressure estimation using smart watch. (May 2022)
- Main Title:
- A new approach for daily life Blood-Pressure estimation using smart watch
- Authors:
- He, Jiayu
Ou, Jianlin
He, An
Shu, Lin
Liu, Tao
Qu, Ruowen
Xu, Xiangmin
Chen, Zhuoming
Yan, Yifeng - Abstract:
- Highlights: Wearable ECG and PPG dataset was established by using a highly integrated smart watch. The features of PPG and ECG were fused to extract blood-pressure relevance information. The 5-s physiological data segments were selected by using the outlier detection algorithm. A calib-free mode and a calib-based mode were presented for blood-pressure monitoring. Abstract: Hypertension has become a major factor affecting people's health. Timely monitoring and prevention of hypertension are of great significance. Most blood-pressure monitoring devices have redundant accessories and complex operations, which are not suitable for daily life applications. To solve these problems, we designed an application-level smart watch that can calculate the PAT feature using simultaneously collected ECG and PPG signals. By fusing the time–frequency-domain features of PPG and the correlation matrix between pulses, the information related to blood pressure in physiological signals was comprehensively extracted. Most of unstable signal segments can be eliminated and the impact of signal disturbances on overall accuracy will be reduced. This paper proposed two blood-pressure estimation modes: a two-step calib-free mode and a personal calibration mode based on transfer learning. The results on our self-established dataset (36 normotensive subjects and 40 hypertensive subjects) indicated that the two-step calib-free mode could estimate blood pressure with accuracy of 0.23 ± 6.1 mmHg andHighlights: Wearable ECG and PPG dataset was established by using a highly integrated smart watch. The features of PPG and ECG were fused to extract blood-pressure relevance information. The 5-s physiological data segments were selected by using the outlier detection algorithm. A calib-free mode and a calib-based mode were presented for blood-pressure monitoring. Abstract: Hypertension has become a major factor affecting people's health. Timely monitoring and prevention of hypertension are of great significance. Most blood-pressure monitoring devices have redundant accessories and complex operations, which are not suitable for daily life applications. To solve these problems, we designed an application-level smart watch that can calculate the PAT feature using simultaneously collected ECG and PPG signals. By fusing the time–frequency-domain features of PPG and the correlation matrix between pulses, the information related to blood pressure in physiological signals was comprehensively extracted. Most of unstable signal segments can be eliminated and the impact of signal disturbances on overall accuracy will be reduced. This paper proposed two blood-pressure estimation modes: a two-step calib-free mode and a personal calibration mode based on transfer learning. The results on our self-established dataset (36 normotensive subjects and 40 hypertensive subjects) indicated that the two-step calib-free mode could estimate blood pressure with accuracy of 0.23 ± 6.1 mmHg and 0.63 ± 9.35 mmHg for DBP and SBP respectively, which was better than previous calib-free methods. Through the personal calibration mode, the estimation accuracy reached 0.02 ± 5.94 mmHg for DBP and 0.3 ± 7.69 mmHg for SBP, which complied with the Association for the Advancement of Medical Instrumentation standard. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 75(2022)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 75(2022)
- Issue Display:
- Volume 75, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 75
- Issue:
- 2022
- Issue Sort Value:
- 2022-0075-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05
- Subjects:
- Blood-pressure estimation -- Intelligent wearable watch -- Transfer learning
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2022.103616 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21323.xml