New pulse oximetry detection based on the light absorbance ratio as determined from amplitude modulation indexes in the time and frequency domains. (May 2022)
- Record Type:
- Journal Article
- Title:
- New pulse oximetry detection based on the light absorbance ratio as determined from amplitude modulation indexes in the time and frequency domains. (May 2022)
- Main Title:
- New pulse oximetry detection based on the light absorbance ratio as determined from amplitude modulation indexes in the time and frequency domains
- Authors:
- Kainan, Pattana
Sinchai, Ananta
Tuwanut, Panwit
Wardkein, Paramote - Abstract:
- Highlights: The novel method for calculating R from Modulation Index; R = μ RED μ IR . A new mathematical model for estimating Sp O 2 in the frequency domain is proposed. Demodulators and BPFs are unnecessary to calculate R . Motion Artifact removal. Abstract: The Pandemic COVID-19 situation, a pulse Oximetry is significant to detect a varying blood oxygen saturation of a patient who needed the device to operate with continuous, rapid, high accuracy, and immune of moving artifacts. In this article, three main schemes for low-complexity pulse oximetry detection are proposed. In the first scheme, the light absorbance ratio ( R ) is obtained by separating the red and infrared photoplethysmography (PPG) amplitude modulation (AM) signals from the frequency-division multiplexing (FDM) signal with two different bandpass filters (BPFs), determining the ratio of modulation index of red and infrared PPG AM signals. In the second scheme, the output PPG AM signals for the red and infrared light wavelengths from the BPFs are transformed into the frequency domain such that the AC components of both PPG AM signals are the magnitudes of the highest peaks in their respective sidebands, while the DC components are the magnitude of their carrier frequencies; then, the AC/DC ratio of the red PPG AM signal is divided by the AC/DC ratio of the infrared PPG AM signal is R . In the last scheme, the FDM signal is transformed into the frequency domain without being passed through any BPF, and R isHighlights: The novel method for calculating R from Modulation Index; R = μ RED μ IR . A new mathematical model for estimating Sp O 2 in the frequency domain is proposed. Demodulators and BPFs are unnecessary to calculate R . Motion Artifact removal. Abstract: The Pandemic COVID-19 situation, a pulse Oximetry is significant to detect a varying blood oxygen saturation of a patient who needed the device to operate with continuous, rapid, high accuracy, and immune of moving artifacts. In this article, three main schemes for low-complexity pulse oximetry detection are proposed. In the first scheme, the light absorbance ratio ( R ) is obtained by separating the red and infrared photoplethysmography (PPG) amplitude modulation (AM) signals from the frequency-division multiplexing (FDM) signal with two different bandpass filters (BPFs), determining the ratio of modulation index of red and infrared PPG AM signals. In the second scheme, the output PPG AM signals for the red and infrared light wavelengths from the BPFs are transformed into the frequency domain such that the AC components of both PPG AM signals are the magnitudes of the highest peaks in their respective sidebands, while the DC components are the magnitude of their carrier frequencies; then, the AC/DC ratio of the red PPG AM signal is divided by the AC/DC ratio of the infrared PPG AM signal is R . In the last scheme, the FDM signal is transformed into the frequency domain without being passed through any BPF, and R is obtained in the same way as in the same second scheme. Experimental results obtained by using the first scheme have an average error of about 0.7138%, for the second and the last scheme have an average error of about 1%, and all the methods agree with the corresponding mathematical model. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 75(2022)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 75(2022)
- Issue Display:
- Volume 75, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 75
- Issue:
- 2022
- Issue Sort Value:
- 2022-0075-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05
- Subjects:
- Pulse oximetry -- Photoplethysmography -- Light absorbance ratio -- Motion artifact -- Amplitude modulation -- Frequency-division multiplexing
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2022.103627 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21304.xml