Evaluation of robustly optimised intensity modulated proton therapy for nasopharyngeal carcinoma. (March 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of robustly optimised intensity modulated proton therapy for nasopharyngeal carcinoma. (March 2022)
- Main Title:
- Evaluation of robustly optimised intensity modulated proton therapy for nasopharyngeal carcinoma
- Authors:
- Scandurra, Daniel
Meijer, Tineke W.H.
Free, Jeffrey
van den Hoek, Johanna G.M.
Kelder, Lotta
Oldehinkel, Edwin
Steenbakkers, Roel J.H.M.
Both, Stefan
Langendijk, Johannes A. - Abstract:
- Highlights: First study to report clinical experiences using robustly optimised IMPT in nasopharyngeal cancer. Dose accumulation performed on robustly evaluated weekly repeat CTs for 25 patients. Plan adaptation rate was low (2/25 patients). Target coverage, critical organ maximum doses and NTCP were stable despite uncertainties and anatomy changes. Abstract: Background and purpose: To evaluate the dosimetric changes occurring over the treatment course for nasopharyngeal carcinoma (NPC) patients treated with robustly optimised intensity modulated proton therapy (IMPT). Materials and methods: 25 NPC patients were treated to two dose levels (CTV1: 70 Gy, CTV2: 54.25 Gy) with robustly optimised IMPT plans. Robustness evaluation was performed over 28 error scenarios using voxel-wise minimum distributions to assess target coverage and voxel-wise maximum distributions to assess possible hotspots and critical organ doses. Daily CBCT was used for positioning and weekly repeat CTs (rCT) were taken, on which the plan dose was recalculated and robustly evaluated. Deformable image registration was used to warp and accumulate the nominal, voxel-wise minimum and maximum rCT dose distributions. Changes to target coverage, critical organ and normal tissue dose between the accumulated and planned doses were investigated. Results: 2 patients required a plan adaptation due to reduced target coverage. The D98% in the accumulated voxel-wise minimum distribution was higher than planned for CTV1Highlights: First study to report clinical experiences using robustly optimised IMPT in nasopharyngeal cancer. Dose accumulation performed on robustly evaluated weekly repeat CTs for 25 patients. Plan adaptation rate was low (2/25 patients). Target coverage, critical organ maximum doses and NTCP were stable despite uncertainties and anatomy changes. Abstract: Background and purpose: To evaluate the dosimetric changes occurring over the treatment course for nasopharyngeal carcinoma (NPC) patients treated with robustly optimised intensity modulated proton therapy (IMPT). Materials and methods: 25 NPC patients were treated to two dose levels (CTV1: 70 Gy, CTV2: 54.25 Gy) with robustly optimised IMPT plans. Robustness evaluation was performed over 28 error scenarios using voxel-wise minimum distributions to assess target coverage and voxel-wise maximum distributions to assess possible hotspots and critical organ doses. Daily CBCT was used for positioning and weekly repeat CTs (rCT) were taken, on which the plan dose was recalculated and robustly evaluated. Deformable image registration was used to warp and accumulate the nominal, voxel-wise minimum and maximum rCT dose distributions. Changes to target coverage, critical organ and normal tissue dose between the accumulated and planned doses were investigated. Results: 2 patients required a plan adaptation due to reduced target coverage. The D98% in the accumulated voxel-wise minimum distribution was higher than planned for CTV1 in 24/25 patients and for CTV2 in 20/25 patients. Maximum doses to the critical organs remained acceptable in all patients. Other normal tissue doses showed some variation as a result of soft tissue deformations and weight change. Normal tissue complication probabilities for grade ≥ 2 dysphagia and grade ≥ 2 xerostomia remained similar to planned values. Conclusion: Robustly optimised IMPT plans, in combination with volumetric verification imaging and adaptive planning, provided robust target coverage and acceptable OAR dose variation in our NPC cohort when accumulated over longitudinal data. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 168(2022)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 168(2022)
- Issue Display:
- Volume 168, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 168
- Issue:
- 2022
- Issue Sort Value:
- 2022-0168-2022-0000
- Page Start:
- 221
- Page End:
- 228
- Publication Date:
- 2022-03
- Subjects:
- Head and neck -- Nasopharyngeal cancer -- Proton therapy -- IMPT -- Robust optimisation
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2022.01.043 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21292.xml