The value of lamp to rule out imported malaria diagnosis: a retrospective observational study in Milan, Italy. Issue 6 (3rd June 2022)
- Record Type:
- Journal Article
- Title:
- The value of lamp to rule out imported malaria diagnosis: a retrospective observational study in Milan, Italy. Issue 6 (3rd June 2022)
- Main Title:
- The value of lamp to rule out imported malaria diagnosis: a retrospective observational study in Milan, Italy
- Authors:
- Giacomelli, Andrea
Monti, Maria Elena
Grande, Romualdo
Oreni, Letizia
Galimberti, Laura
Ridolfo, Anna Lisa
Bonazzetti, Cecilia
Sabaini, Federico
Cordier, Laura
Zambelli, Agostino
Rizzardini, Giuliano
Galli, Massimo
Antinori, Spinello - Abstract:
- Abstract: Background: The diagnosis of malaria in returning travellers could be a challenge in non-endemic settings. We aimed to assess the performance of LAMP in comparison with standard conventional diagnostic methods using real-time-polymerase chain reaction (PCR) in case of discordant results. Methods: All travellers returning from malaria-endemic areas who presented to our Emergency Department (ED) from January 2017 to December 2020 with signs and symptoms suggestive for malaria were included. Blood microscopy was the reference diagnostic method applied at our laboratory with LAMP implemented as an additional method to aid in malaria diagnosis. PCR was employed only in case of between test's discordant results. Sensitivity and specificity of microscopy compared to LAMP were calculated with the confidence interval of 95%. Results: Four-hundred and eight patients (55.6% male, median age 42 years) were screened for malaria. The diagnosis was confirmed in 49 cases (12%): 44 cases (90%) caused by Plasmodium falciparum . Peripheral blood smear missed to identify three malaria cases, which tested positive with LAMP and PCR. One case of malaria caused by P. malariae in a naive tourist, one case by P. falciparum in a semi-immune pregnant women and one case by P. falciparum in a previously treated semi-immune patient. All the discordant cases were characterized by a very low parasitaemia. Microscopy when compared to LAMP showed a sensitivity of 93.9% (95% confidence interval (CI)Abstract: Background: The diagnosis of malaria in returning travellers could be a challenge in non-endemic settings. We aimed to assess the performance of LAMP in comparison with standard conventional diagnostic methods using real-time-polymerase chain reaction (PCR) in case of discordant results. Methods: All travellers returning from malaria-endemic areas who presented to our Emergency Department (ED) from January 2017 to December 2020 with signs and symptoms suggestive for malaria were included. Blood microscopy was the reference diagnostic method applied at our laboratory with LAMP implemented as an additional method to aid in malaria diagnosis. PCR was employed only in case of between test's discordant results. Sensitivity and specificity of microscopy compared to LAMP were calculated with the confidence interval of 95%. Results: Four-hundred and eight patients (55.6% male, median age 42 years) were screened for malaria. The diagnosis was confirmed in 49 cases (12%): 44 cases (90%) caused by Plasmodium falciparum . Peripheral blood smear missed to identify three malaria cases, which tested positive with LAMP and PCR. One case of malaria caused by P. malariae in a naive tourist, one case by P. falciparum in a semi-immune pregnant women and one case by P. falciparum in a previously treated semi-immune patient. All the discordant cases were characterized by a very low parasitaemia. Microscopy when compared to LAMP showed a sensitivity of 93.9% (95% confidence interval (CI) 83.1–98.7%) and a specificity of 100% (95% CI 98.9–100%). Conclusions: In our non-endemic setting LAMP was able to identify malaria cases with low-level parasitaemia otherwise missed by blood microscopy. … (more)
- Is Part Of:
- Infectious diseases. Volume 54:Issue 6(2022)
- Journal:
- Infectious diseases
- Issue:
- Volume 54:Issue 6(2022)
- Issue Display:
- Volume 54, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 54
- Issue:
- 6
- Issue Sort Value:
- 2022-0054-0006-0000
- Page Start:
- 410
- Page End:
- 417
- Publication Date:
- 2022-06-03
- Subjects:
- Plasmodium falciparum -- non-falciparum Plasmodium -- imported malaria -- molecular diagnosis -- loop-mediated isothermal amplification -- polymerase chain reaction
Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
616.9 - Journal URLs:
- http://www.tandfonline.com/loi/infd19#.VksX11Inzcs ↗
http://informahealthcare.com/loi/inf ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/23744235.2021.2023754 ↗
- Languages:
- English
- ISSNs:
- 2374-4235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21293.xml