Feasibility of cardiac-synchronized quantitative T1 and T2 mapping on a hybrid 1.5 Tesla magnetic resonance imaging and linear accelerator system. (January 2022)
- Record Type:
- Journal Article
- Title:
- Feasibility of cardiac-synchronized quantitative T1 and T2 mapping on a hybrid 1.5 Tesla magnetic resonance imaging and linear accelerator system. (January 2022)
- Main Title:
- Feasibility of cardiac-synchronized quantitative T1 and T2 mapping on a hybrid 1.5 Tesla magnetic resonance imaging and linear accelerator system
- Authors:
- Akdag, Osman
Mandija, Stefano
van Lier, Astrid L.H.M.W.
Borman, Pim T.S.
Schakel, Tim
Alberts, Eveline
van der Heide, Oscar
Hassink, Rutger J.
Verhoeff, Joost J.C.
Mohamed Hoesein, Firdaus A.A.
Raaymakers, Bas W.
Fast, Martin F. - Abstract:
- Abstract: Background and Purpose: The heart is important in radiotherapy either as target or organ at risk. Quantitative T1 and T2 cardiac magnetic resonance imaging (qMRI) may aid in target definition for cardiac radioablation, and imaging biomarker for cardiotoxicity assessment. Hybrid MR-linac devices could facilitate daily cardiac qMRI of the heart in radiotherapy. The aim of this work was therefore to enable cardiac-synchronized T1 and T2 mapping on a 1.5 T MR-linac and test the reproducibility of these sequences on phantoms and in vivo between the MR-linac and a diagnostic 1.5 T MRI scanner. Materials and methods: Cardiac-synchronized MRI was performed on the MR-linac using a wireless peripheral pulse-oximeter unit. Diagnostically used T1 and T2 mapping sequences were acquired twice on the MR-linac and on a 1.5 T MR-simulator for a gel phantom and 5 healthy volunteers in breath-hold. Phantom T1 and T2 values were compared to gold-standard measurements and percentage errors (PE) were computed, where negative/positive PE indicate underestimations/overestimations. Manually selected regions-of-interest were used for in vivo intra/inter scanner evaluation. Results: Cardiac-synchronized T1 and T2 qMRI was enabled after successful hardware installation on the MR-linac. From the phantom experiments, the measured T1 /T2 relaxation times had a maximum percentage error (PE) of −4.4%/−8.8% on the MR-simulator and a maximum PE of −3.2%/+8.6% on the MR-linac. Mean T1 /T2 of theAbstract: Background and Purpose: The heart is important in radiotherapy either as target or organ at risk. Quantitative T1 and T2 cardiac magnetic resonance imaging (qMRI) may aid in target definition for cardiac radioablation, and imaging biomarker for cardiotoxicity assessment. Hybrid MR-linac devices could facilitate daily cardiac qMRI of the heart in radiotherapy. The aim of this work was therefore to enable cardiac-synchronized T1 and T2 mapping on a 1.5 T MR-linac and test the reproducibility of these sequences on phantoms and in vivo between the MR-linac and a diagnostic 1.5 T MRI scanner. Materials and methods: Cardiac-synchronized MRI was performed on the MR-linac using a wireless peripheral pulse-oximeter unit. Diagnostically used T1 and T2 mapping sequences were acquired twice on the MR-linac and on a 1.5 T MR-simulator for a gel phantom and 5 healthy volunteers in breath-hold. Phantom T1 and T2 values were compared to gold-standard measurements and percentage errors (PE) were computed, where negative/positive PE indicate underestimations/overestimations. Manually selected regions-of-interest were used for in vivo intra/inter scanner evaluation. Results: Cardiac-synchronized T1 and T2 qMRI was enabled after successful hardware installation on the MR-linac. From the phantom experiments, the measured T1 /T2 relaxation times had a maximum percentage error (PE) of −4.4%/−8.8% on the MR-simulator and a maximum PE of −3.2%/+8.6% on the MR-linac. Mean T1 /T2 of the myocardium were 1012 ± 34/51 ± 2 ms on the MR-simulator and 1034 ± 42/51 ± 1 ms on the MR-linac. Conclusions: Accurate cardiac-synchronized T1 and T2 mapping is feasible on a 1.5 T MR-linac and might enable novel plan adaptation workflows and cardiotoxicity assessments. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 21(2022)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 21(2022)
- Issue Display:
- Volume 21, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 21
- Issue:
- 2022
- Issue Sort Value:
- 2022-0021-2022-0000
- Page Start:
- 153
- Page End:
- 159
- Publication Date:
- 2022-01
- Subjects:
- MR-linac -- MRI -- Quantitative cardiac MRI -- MRI-guided radiotherapy -- Cardiac MR-linac
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2022.02.017 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21302.xml