Marsolo, Keith - Abstract:
- Abstract: Objective: To empirically explore how pragmatic clinical trials (PCTs) that used real-world data (RWD) assessed study-specific fitness-for-use. Methods: We conducted interviews and surveys with PCT teams who used electronic health record (EHR) data to ascertain endpoints. The survey cataloged key concerns about RWD, activities used to assess data fitness-for-use, and related barriers encountered by study teams. Patterns and commonalities across trials were used to develop recommendations for study-specific fitness-for-use assessments. Results: Of 15 invited trial teams, 7 interviews were conducted. Of 31 invited trials, 15 responded to the survey. Most respondents had prior experience using RWD (93%). Major concerns about EHR data were data reliability, missingness or incompleteness of EHR elements, variation in data quality across study sites, and presence of implausible or incorrect values. Although many PCTs conducted fitness-for-use activities (eg, data quality assessments, 11/14, 79%), less than a quarter did so before choosing a data source. Fitness-for-use activities, findings, and resulting study design changes were not often publically documented. Overall costs and personnel costs were barriers to fitness-for-use assessments. Discussion: These results support three recommendations for PCTs that use EHR data for endpoint ascertainment. Trials should detail the rationale and plan for study-specific fitness-for-use activities, conduct study-specificAbstract: Objective: To empirically explore how pragmatic clinical trials (PCTs) that used real-world data (RWD) assessed study-specific fitness-for-use. Methods: We conducted interviews and surveys with PCT teams who used electronic health record (EHR) data to ascertain endpoints. The survey cataloged key concerns about RWD, activities used to assess data fitness-for-use, and related barriers encountered by study teams. Patterns and commonalities across trials were used to develop recommendations for study-specific fitness-for-use assessments. Results: Of 15 invited trial teams, 7 interviews were conducted. Of 31 invited trials, 15 responded to the survey. Most respondents had prior experience using RWD (93%). Major concerns about EHR data were data reliability, missingness or incompleteness of EHR elements, variation in data quality across study sites, and presence of implausible or incorrect values. Although many PCTs conducted fitness-for-use activities (eg, data quality assessments, 11/14, 79%), less than a quarter did so before choosing a data source. Fitness-for-use activities, findings, and resulting study design changes were not often publically documented. Overall costs and personnel costs were barriers to fitness-for-use assessments. Discussion: These results support three recommendations for PCTs that use EHR data for endpoint ascertainment. Trials should detail the rationale and plan for study-specific fitness-for-use activities, conduct study-specific fitness-for-use assessments early in the prestudy phase to inform study design changes before the trial begins, and share results of fitness-for-use assessments and description of relevant challenges and facilitators. Conclusion: These recommendations can help researchers and end-users of real-world evidence improve characterization of RWD reliability and relevance in the PCT-specific context. … (more)
- Is Part Of:
- Journal of the American Medical Informatics Association. Volume 29:Number 5(2022)
- Journal:
- Journal of the American Medical Informatics Association
- Issue:
- Volume 29:Number 5(2022)
- Issue Display:
- Volume 29, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 29
- Issue:
- 5
- Issue Sort Value:
- 2022-0029-0005-0000
- Page Start:
- 798
- Page End:
- 804
- Publication Date:
- 2022-02-16
- Subjects:
- data accuracy -- research design -- electronic health records -- pragmatic clinical trials as topic
Medical informatics -- Periodicals
Information Services -- Periodicals
Medical Informatics -- Periodicals
Médecine -- Informatique -- Périodiques
Informatica
Geneeskunde
Informatique médicale
Computer network resources
Electronic journals
610.285 - Journal URLs:
- http://jamia.bmj.com/ ↗
http://www.jamia.org ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=76 ↗
http://www.sciencedirect.com/science/journal/10675027 ↗
http://jamia.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/jamia/ocac004 ↗
- Languages:
- English
- ISSNs:
- 1067-5027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4689.025000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21290.xml