Inter-observer variability of organ contouring for preclinical studies with cone beam Computed Tomography imaging. (January 2022)
- Record Type:
- Journal Article
- Title:
- Inter-observer variability of organ contouring for preclinical studies with cone beam Computed Tomography imaging. (January 2022)
- Main Title:
- Inter-observer variability of organ contouring for preclinical studies with cone beam Computed Tomography imaging
- Authors:
- Lappas, Georgios
Staut, Nick
Lieuwes, Natasja G.
Biemans, Rianne
Wolfs, Cecile J.A.
van Hoof, Stefan J.
Dubois, Ludwig J.
Verhaegen, Frank - Abstract:
- Abstract: Background and purpose: In preclinical radiation studies, there is great interest in quantifying the radiation response of healthy tissues. Manual contouring has significant impact on the treatment-planning because of variation introduced by human interpretation. This results in inconsistencies when assessing normal tissue volumes. Evaluation of these discrepancies can provide a better understanding on the limitations of the current preclinical radiation workflow. In the present work, interobserver variability (IOV) in manual contouring of rodent normal tissues on cone-beam Computed Tomography, in head and thorax regions was evaluated. Materials and methods: Two animal technicians performed manually (assisted) contouring of normal tissues located within the thorax and head regions of rodents, 20 cases per body site. Mean surface distance (MSD), displacement of center of mass (ΔCoM), DICE similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD95 ) were calculated between the contours of the two observers to evaluate the IOV. Results: For the thorax organs, right lung had the lowest IOV (ΔCoM: 0.08 ± 0.04 mm, DSC: 0.96 ± 0.01, MSD:0.07 ± 0.01 mm, HD95 :0.20 ± 0.03 mm) while spinal cord, the highest IOV (ΔCoM:0.5 ± 0.3 mm, DSC:0.81 ± 0.05, MSD:0.14 ± 0.03 mm, HD95 :0.8 ± 0.2 mm). Regarding head organs, right eye demonstrated the lowest IOV (ΔCoM:0.12 ± 0.08 mm, DSC: 0.93 ± 0.02, MSD: 0.15 ± 0.04 mm, HD95 : 0.29 ± 0.07 mm) while complete brain, theAbstract: Background and purpose: In preclinical radiation studies, there is great interest in quantifying the radiation response of healthy tissues. Manual contouring has significant impact on the treatment-planning because of variation introduced by human interpretation. This results in inconsistencies when assessing normal tissue volumes. Evaluation of these discrepancies can provide a better understanding on the limitations of the current preclinical radiation workflow. In the present work, interobserver variability (IOV) in manual contouring of rodent normal tissues on cone-beam Computed Tomography, in head and thorax regions was evaluated. Materials and methods: Two animal technicians performed manually (assisted) contouring of normal tissues located within the thorax and head regions of rodents, 20 cases per body site. Mean surface distance (MSD), displacement of center of mass (ΔCoM), DICE similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD95 ) were calculated between the contours of the two observers to evaluate the IOV. Results: For the thorax organs, right lung had the lowest IOV (ΔCoM: 0.08 ± 0.04 mm, DSC: 0.96 ± 0.01, MSD:0.07 ± 0.01 mm, HD95 :0.20 ± 0.03 mm) while spinal cord, the highest IOV (ΔCoM:0.5 ± 0.3 mm, DSC:0.81 ± 0.05, MSD:0.14 ± 0.03 mm, HD95 :0.8 ± 0.2 mm). Regarding head organs, right eye demonstrated the lowest IOV (ΔCoM:0.12 ± 0.08 mm, DSC: 0.93 ± 0.02, MSD: 0.15 ± 0.04 mm, HD95 : 0.29 ± 0.07 mm) while complete brain, the highest IOV (ΔCoM: 0.2 ± 0.1 mm, DSC: 0.94 ± 0.02, MSD: 0.3 ± 0.1 mm, HD95 : 0.5 ± 0.1 mm). Conclusions: Our findings reveal small IOV, within the sub-mm range, for thorax and head normal tissues in rodents. The set of contours can serve as a basis for developing an automated delineation method for e.g., treatment planning. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 21(2022)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 21(2022)
- Issue Display:
- Volume 21, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 21
- Issue:
- 2022
- Issue Sort Value:
- 2022-0021-2022-0000
- Page Start:
- 11
- Page End:
- 17
- Publication Date:
- 2022-01
- Subjects:
- Organ contouring -- Interobserver variability -- Preclinical -- CT
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2022.01.002 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21302.xml