Dynamic nature of the LVOT following transcatheter mitral valve replacement with LAMPOON: new insights from post-procedure imaging. (2nd May 2021)
- Record Type:
- Journal Article
- Title:
- Dynamic nature of the LVOT following transcatheter mitral valve replacement with LAMPOON: new insights from post-procedure imaging. (2nd May 2021)
- Main Title:
- Dynamic nature of the LVOT following transcatheter mitral valve replacement with LAMPOON: new insights from post-procedure imaging
- Authors:
- Kohli, Keshav
Wei, Zhenglun Alan
Sadri, Vahid
Khan, Jaffar M
Lisko, John C
Netto, Tiffany
Greenbaum, Adam B
Blanke, Philipp
Oshinski, John N
Lederman, Robert J
Yoganathan, Ajit P
Babaliaros, Vasilis C - Abstract:
- Abstract: Aims: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. Methods and results: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects ( N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient > 30 mmHg or LVOT effective orifice area (EOA) ≤ 1.15 cm 2 ]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction ( n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm 2 for early-systole, peak flow, mid-systole, and end-systole, respectively). Conclusion: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas acrossAbstract: Aims: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. Methods and results: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects ( N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient > 30 mmHg or LVOT effective orifice area (EOA) ≤ 1.15 cm 2 ]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction ( n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm 2 for early-systole, peak flow, mid-systole, and end-systole, respectively). Conclusion: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas across systole. The authors recommend the use of phase-specific threshold values for skirt neo-LVOT area to guide future patient selection for this procedure. LVOT EOA is a 'flow-independent' metric which has the potential to aid in characterizing LVOT obstruction severity. Graphical Abstract: … (more)
- Is Part Of:
- European heart journal. Volume 23:Number 5(2022)
- Journal:
- European heart journal
- Issue:
- Volume 23:Number 5(2022)
- Issue Display:
- Volume 23, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2022-0023-0005-0000
- Page Start:
- 650
- Page End:
- 662
- Publication Date:
- 2021-05-02
- Subjects:
- neo-LVOT -- left ventricular outflow tract obstruction -- transcatheter mitral valve replacement -- transcatheter electrosurgery -- TMVR -- LAMPOON
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeab074 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21299.xml