Factors influencing inferior vena cava diameter and its respiratory variation: Simultaneous comparison with hemodynamic data. Issue 5 (May 2022)
- Record Type:
- Journal Article
- Title:
- Factors influencing inferior vena cava diameter and its respiratory variation: Simultaneous comparison with hemodynamic data. Issue 5 (May 2022)
- Main Title:
- Factors influencing inferior vena cava diameter and its respiratory variation: Simultaneous comparison with hemodynamic data
- Authors:
- Kawata, Takayuki
Daimon, Masao
Nakanishi, Koki
Kimura, Koichi
Sawada, Naoko
Nakao, Tomoko
Hirokawa, Megumi
Ishiwata, Jumpei
Takeda, Norifumi
Yatomi, Yutaka
Komuro, Issei - Abstract:
- Highlights: To recognize factors other than right atrial pressure (RAP) that may influence inferior vena cava (IVC) measurements is critical. Significant tricuspid regurgitation, larger body surface area, and younger age are associated with the IVC distension. In contrast, IVC collapsibility index is influenced only by RAP. Abstract: Background: Ultrasound assessment of inferior vena cava (IVC) diameter and its respiratory variation is widely used to estimate right atrial pressure (RAP). Generally, the IVC distends as the RAP rises; however, there may be discrepancies between the values. Therefore, it is critical to recognize clinical factors other than RAP that may influence IVC measurements. Methods: We obtained the IVC maximum diameter and IVC collapsibility index (IVCCI) simultaneously during right-heart catheterization in 71 consecutive patients. Then, we assessed various clinical and hemodynamic factors to elucidate the independent determinants of IVC measurements. Moreover, we tried to generate the regression equation to estimate mean RAP from the IVC maximum diameter and IVCCI. Results: The mean IVC maximum diameter and IVCCI were 15 ± 4 mm and 51 ± 15%, respectively. In stepwise multivariate analysis, the higher mean RAP (β = 0.52; p < 0.0001), the presence of significant tricuspid regurgitation (β = 0.31; p = 0.0005), a larger body surface area (β = 0.22; p = 0.0017), and younger age (β = -0.18; p = 0.049) were independently associated with the IVC maximumHighlights: To recognize factors other than right atrial pressure (RAP) that may influence inferior vena cava (IVC) measurements is critical. Significant tricuspid regurgitation, larger body surface area, and younger age are associated with the IVC distension. In contrast, IVC collapsibility index is influenced only by RAP. Abstract: Background: Ultrasound assessment of inferior vena cava (IVC) diameter and its respiratory variation is widely used to estimate right atrial pressure (RAP). Generally, the IVC distends as the RAP rises; however, there may be discrepancies between the values. Therefore, it is critical to recognize clinical factors other than RAP that may influence IVC measurements. Methods: We obtained the IVC maximum diameter and IVC collapsibility index (IVCCI) simultaneously during right-heart catheterization in 71 consecutive patients. Then, we assessed various clinical and hemodynamic factors to elucidate the independent determinants of IVC measurements. Moreover, we tried to generate the regression equation to estimate mean RAP from the IVC maximum diameter and IVCCI. Results: The mean IVC maximum diameter and IVCCI were 15 ± 4 mm and 51 ± 15%, respectively. In stepwise multivariate analysis, the higher mean RAP (β = 0.52; p < 0.0001), the presence of significant tricuspid regurgitation (β = 0.31; p = 0.0005), a larger body surface area (β = 0.22; p = 0.0017), and younger age (β = -0.18; p = 0.049) were independently associated with the IVC maximum diameter. Only the mean RAP was independently associated with the IVCCI (β = -0.45; p < 0.0001). The regression equation (R 2 = 0.43, p < 0.0001) was as follows: estimated mean RAP = 3.7 + 0.62 × maximum IVC diameter / BSA - 0.07 × IVCCI. Conclusion: Distension of the IVC mainly occurs with elevated RAP. However, the presence of significant tricuspid regurgitation, a larger body surface area, and younger age are associated with the IVC maximum diameter, independently of RAP. Interestingly, IVCCI is influenced only by RAP. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Journal of cardiology. Volume 79:Issue 5(2022)
- Journal:
- Journal of cardiology
- Issue:
- Volume 79:Issue 5(2022)
- Issue Display:
- Volume 79, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 79
- Issue:
- 5
- Issue Sort Value:
- 2022-0079-0005-0000
- Page Start:
- 642
- Page End:
- 647
- Publication Date:
- 2022-05
- Subjects:
- Right atrial pressure -- Inferior vena cava diameter -- Respiratory variation
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/09145087 ↗
http://www.sciencedirect.com/science/journal/09145087 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jjcc.2021.11.022 ↗
- Languages:
- English
- ISSNs:
- 0914-5087
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.864200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21286.xml