674. Evaluation of the Access Bio CareStart™ Rapid SARS-CoV-2 Antigen Test in Asymptomatic Individuals Tested at a Community Mass-testing Program in Western Massachusetts. (4th December 2021)
- Record Type:
- Journal Article
- Title:
- 674. Evaluation of the Access Bio CareStart™ Rapid SARS-CoV-2 Antigen Test in Asymptomatic Individuals Tested at a Community Mass-testing Program in Western Massachusetts. (4th December 2021)
- Main Title:
- 674. Evaluation of the Access Bio CareStart™ Rapid SARS-CoV-2 Antigen Test in Asymptomatic Individuals Tested at a Community Mass-testing Program in Western Massachusetts
- Authors:
- Matias, Wilfredo
suliman, Sara
Fulcher, Isabel
Molano, Francisco
Collins, Shannon
Uceta, Elizabeth
Zhu, Jack
Paxton, Ryan
Gonsalves, Sean
Harden, Maegan
Fisher, Marissa
Meldrim, Jim
Gabriel, Stacey
Franke, Molly
Hung, Deborah
Smole, Sandra
Madoff, Lawrence
Ivers, Louise - Abstract:
- Abstract: Background: Point-of-care antigen-detecting rapid diagnostic tests (RDTs) to detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) represent a scalable tool for surveillance of active SARS-CoV-2 infections in the population. Data on the performance of these tests in real-world community settings will be paramount for their implementation to combat the COVID-19 pandemic. Methods: We evaluated the performance characteristics of the CareStart TM COVID-19 Antigen Test (CareStart) in a community testing site in Holyoke, Massachusetts. We compared CareStart to a SARS-CoV-2 reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) reference, both using anterior nasal swab samples. We calculated the sensitivity, specificity, and the expected positive and negative predictive values at different SARS-CoV-2 prevalence estimates. Results: We performed 666 total tests on 591 unique individuals. 573 (86%) were asymptomatic. There were 52 positive tests by RT-qPCR. The sensitivity of CareStart was 49.0% (95% Confidence Interval (CI): 34.8 – 63.4) and specificity was 99.5% (95% CI: 98.5 – 99.9). Among positive RT-qPCR tests, the median cycle threshold (Ct) was significantly lower in samples that tested positive on CareStart. Using a Ct less than or equal to 30 as a benchmark for positivity increased the sensitivity of the test to 64.9% (95% CI: 47.5 – 79.8). Performance characteristics of CareStart test results benchmarked against the RT-qPCR goldAbstract: Background: Point-of-care antigen-detecting rapid diagnostic tests (RDTs) to detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) represent a scalable tool for surveillance of active SARS-CoV-2 infections in the population. Data on the performance of these tests in real-world community settings will be paramount for their implementation to combat the COVID-19 pandemic. Methods: We evaluated the performance characteristics of the CareStart TM COVID-19 Antigen Test (CareStart) in a community testing site in Holyoke, Massachusetts. We compared CareStart to a SARS-CoV-2 reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) reference, both using anterior nasal swab samples. We calculated the sensitivity, specificity, and the expected positive and negative predictive values at different SARS-CoV-2 prevalence estimates. Results: We performed 666 total tests on 591 unique individuals. 573 (86%) were asymptomatic. There were 52 positive tests by RT-qPCR. The sensitivity of CareStart was 49.0% (95% Confidence Interval (CI): 34.8 – 63.4) and specificity was 99.5% (95% CI: 98.5 – 99.9). Among positive RT-qPCR tests, the median cycle threshold (Ct) was significantly lower in samples that tested positive on CareStart. Using a Ct less than or equal to 30 as a benchmark for positivity increased the sensitivity of the test to 64.9% (95% CI: 47.5 – 79.8). Performance characteristics of CareStart test results benchmarked against the RT-qPCR gold standard (excluding undetermined results). Examples of images of CareStart rapid test showing variable band intensities. N2 gene RT-qPCR Cycle threshold (Ct) values corresponding to positive and negative CareStart rapid antigen test results for all RT-qPCR positive samples (n=52). Conclusion: Our study shows that CareStart has a high specificity and moderate sensitivity. The utility of RDTs, such as CareStart, in mass implementation should prioritize use cases in which a higher specificity is more important, such as triage tests to rule-in active infections in community surveillance programs. Disclosures: All Authors : No reported disclosures … (more)
- Is Part Of:
- Open forum infectious diseases. Volume 8(2021)Supplement 1
- Journal:
- Open forum infectious diseases
- Issue:
- Volume 8(2021)Supplement 1
- Issue Display:
- Volume 8, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2021-0008-0001-0000
- Page Start:
- S439
- Page End:
- S439
- Publication Date:
- 2021-12-04
- Subjects:
- Communicable diseases -- Periodicals
Medical microbiology -- Periodicals
Infection -- Periodicals
616.9 - Journal URLs:
- http://ofid.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/ofid/ofab466.871 ↗
- Languages:
- English
- ISSNs:
- 2328-8957
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21260.xml