Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants. Issue 2 (May 2022)
- Record Type:
- Journal Article
- Title:
- Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants. Issue 2 (May 2022)
- Main Title:
- Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants
- Authors:
- Masuda, T.
Funama, Y.
Nakaura, T.
Sato, T.
Tahara, M.
Masuda, S.
Yoshiura, T.
Gotanda, R.
Arao, K.
Imaizumi, H.
Arao, S.
Hiratsuka, J.
Awai, K. - Abstract:
- Abstract: Introduction: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. Methods: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. Results: In group 1, median CT number and ranges was 345 (211–591) HU in the AAO, 324 (213–567) HU in the PA, and 62 (1–70) HU in the SVC. These values were 465 (308–669) HU, 467 (295–638) HU, and 234 (67–443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). Conclusion: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scoresAbstract: Introduction: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. Methods: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. Results: In group 1, median CT number and ranges was 345 (211–591) HU in the AAO, 324 (213–567) HU in the PA, and 62 (1–70) HU in the SVC. These values were 465 (308–669) HU, 467 (295–638) HU, and 234 (67–443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). Conclusion: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. Implications for practice: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations. … (more)
- Is Part Of:
- Radiography. Volume 28:Issue 2(2022)
- Journal:
- Radiography
- Issue:
- Volume 28:Issue 2(2022)
- Issue Display:
- Volume 28, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 28
- Issue:
- 2
- Issue Sort Value:
- 2022-0028-0002-0000
- Page Start:
- 440
- Page End:
- 446
- Publication Date:
- 2022-05
- Subjects:
- Cardiac computed tomography angiography -- Contrast enhancement -- Pediatric -- Contrast medium -- Congenital heart disease
CT computed tomography -- CCTA cardiac computed tomography angiography -- CHD congenital heart disease -- CM Contrast Media -- FOV field of view -- TBW total body weight -- ROI region of interest -- HU Hounsfield units -- PA pulmonary artery -- AAO ascending aorta -- SVC superior vena cava -- CNR contrast-to-noise ratio -- SD standard deviation -- CTDIvol CT dose volume index -- DLP dose-length product -- ED effective radiation dose
Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2021.11.002 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21247.xml