Dual U-Net residual networks for cardiac magnetic resonance images super-resolution. (May 2022)
- Record Type:
- Journal Article
- Title:
- Dual U-Net residual networks for cardiac magnetic resonance images super-resolution. (May 2022)
- Main Title:
- Dual U-Net residual networks for cardiac magnetic resonance images super-resolution
- Authors:
- Qiu, Defu
Cheng, Yuhu
Wang, Xuesong - Abstract:
- Highlights: Developed the Dual U-Net residual network for network to reconstruct cardiac magnetic resonance images super-resolution. Designed the dual U-Net module. The method effectively improves the super-resolution reconstruction effect of cardiac magnetic resonance images. Abstract: Background and objective: Heart disease is a vital disease that has threatened human health, and is the number one killer of human life. Moreover, with the added influence of recent health factors, its incidence rate keeps showing an upward trend. Today, cardiac magnetic resonance (CMR) imaging can provide a full range of structural and functional information for the heart, and has become an important tool for the diagnosis and treatment of heart disease. Therefore, improving the image resolution of CMR has an important medical value for the diagnosis and condition assessment of heart disease. At present, most single-image super-resolution (SISR) reconstruction methods have some serious problems, such as insufficient feature information mining, difficulty to determine the dependence of each channel of feature map, and reconstruction error when reconstructing high-resolution image. Methods: To solve these problems, we have proposed and implemented a dual U-Net residual network (DURN) for super-resolution of CMR images. Specifically, we first propose a U-Net residual network (URN) model, which is divided into the up-branch and the down-branch. The up-branch is composed of residual blocks andHighlights: Developed the Dual U-Net residual network for network to reconstruct cardiac magnetic resonance images super-resolution. Designed the dual U-Net module. The method effectively improves the super-resolution reconstruction effect of cardiac magnetic resonance images. Abstract: Background and objective: Heart disease is a vital disease that has threatened human health, and is the number one killer of human life. Moreover, with the added influence of recent health factors, its incidence rate keeps showing an upward trend. Today, cardiac magnetic resonance (CMR) imaging can provide a full range of structural and functional information for the heart, and has become an important tool for the diagnosis and treatment of heart disease. Therefore, improving the image resolution of CMR has an important medical value for the diagnosis and condition assessment of heart disease. At present, most single-image super-resolution (SISR) reconstruction methods have some serious problems, such as insufficient feature information mining, difficulty to determine the dependence of each channel of feature map, and reconstruction error when reconstructing high-resolution image. Methods: To solve these problems, we have proposed and implemented a dual U-Net residual network (DURN) for super-resolution of CMR images. Specifically, we first propose a U-Net residual network (URN) model, which is divided into the up-branch and the down-branch. The up-branch is composed of residual blocks and up-blocks to extract and upsample deep features; the down-branch is composed of residual blocks and down-blocks to extract and downsample deep features. Based on the URN model, we employ this a dual U-Net residual network (DURN) model, which combines the extracted deep features of the same position between the first URN and the second URN through residual connection. It can make full use of the features extracted by the first URN to extract deeper features of low-resolution images. Results: When the scale factors are 2, 3, and 4, our DURN can obtain 37.86 dB, 33.96 dB, and 31.65 dB on the Set5 dataset, which shows (i) a maximum improvement of 4.17 dB, 3.55 dB, and 3.22dB over the Bicubic algorithm, and (ii) a minimum improvement of 0.34 dB, 0.14 dB, and 0.11 dB over the LapSRN algorithm. Conclusion: Comprehensive experimental study results on benchmark datasets demonstrate that our proposed DURN can not only achieve better performance for peak signal to noise ratio (PSNR) and structural similarity index (SSIM) values than other state-of-the-art SR image algorithms, but also reconstruct clearer super-resolution CMR images which have richer details, edges, and texture. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 218(2022)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 218(2022)
- Issue Display:
- Volume 218, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 218
- Issue:
- 2022
- Issue Sort Value:
- 2022-0218-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05
- Subjects:
- Super-resolution -- Cardiac magnetic resonance (CMR) -- Single-image super-resolution (SISR) -- U-Net residual network (URN) -- Residual connection
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.106707 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21259.xml