Artificial Intelligence based detection of pneumoperitoneum on CT scans in patients presenting with acute abdominal pain: A clinical diagnostic test accuracy study. Issue 150 (May 2022)
- Record Type:
- Journal Article
- Title:
- Artificial Intelligence based detection of pneumoperitoneum on CT scans in patients presenting with acute abdominal pain: A clinical diagnostic test accuracy study. Issue 150 (May 2022)
- Main Title:
- Artificial Intelligence based detection of pneumoperitoneum on CT scans in patients presenting with acute abdominal pain: A clinical diagnostic test accuracy study
- Authors:
- Brejnebøl, Mathias W.
Nielsen, Yousef W.
Taubmann, Oliver
Eibenberger, Eva
Müller, Felix C. - Abstract:
- Highlights: An AI algorithm can detect pneumoperitoneum in abdominal CT scans. Results demonstrated low sensitivity and a very high specificity. Not suitable as stand-alone screening layer. Does not cause disruptive false alerts in existing workflows. Early warning can help accelerate life-saving treatment for acutely ill patients. Abstract: Purpose: The primary aim was to investigate the diagnostic performance of an Artificial Intelligence (AI) algorithm for pneumoperitoneum detection in patients with acute abdominal pain who underwent an abdominal CT scan. Method: This retrospective diagnostic test accuracy study used a consecutive patient cohort from the Acute High-risk Abdominal patient population at Herlev and Gentofte Hospital, Denmark between January 1, 2019 and September 25, 2019. As reference standard, all studies were rated for pneumoperitoneum (subgroups: none, small, medium, and large amounts) by a gastrointestinal radiology consultant. The index test was a novel AI algorithm based on a sliding window approach with a deep recurrent neural network at its core. The primary outcome was the area under the curve (AUC) of the receiver operating characteristic (ROC). Results: Of 331 included patients (median age 68 years (Range 19–100; 180 women)) 31 patients (9%) had pneumoperitoneum (large: 16, moderate: 7, small: 8). The AUC was 0.77 (95% CI 0.66–0.87). At a specificity of 99% (297/300, 95% CI: 97–100%), sensitivity was 52% (16/31, 95% CI 29–65%), and positiveHighlights: An AI algorithm can detect pneumoperitoneum in abdominal CT scans. Results demonstrated low sensitivity and a very high specificity. Not suitable as stand-alone screening layer. Does not cause disruptive false alerts in existing workflows. Early warning can help accelerate life-saving treatment for acutely ill patients. Abstract: Purpose: The primary aim was to investigate the diagnostic performance of an Artificial Intelligence (AI) algorithm for pneumoperitoneum detection in patients with acute abdominal pain who underwent an abdominal CT scan. Method: This retrospective diagnostic test accuracy study used a consecutive patient cohort from the Acute High-risk Abdominal patient population at Herlev and Gentofte Hospital, Denmark between January 1, 2019 and September 25, 2019. As reference standard, all studies were rated for pneumoperitoneum (subgroups: none, small, medium, and large amounts) by a gastrointestinal radiology consultant. The index test was a novel AI algorithm based on a sliding window approach with a deep recurrent neural network at its core. The primary outcome was the area under the curve (AUC) of the receiver operating characteristic (ROC). Results: Of 331 included patients (median age 68 years (Range 19–100; 180 women)) 31 patients (9%) had pneumoperitoneum (large: 16, moderate: 7, small: 8). The AUC was 0.77 (95% CI 0.66–0.87). At a specificity of 99% (297/300, 95% CI: 97–100%), sensitivity was 52% (16/31, 95% CI 29–65%), and positive likelihood ratio was 52 (95% CI 16–165). When excluding cases with smaller amounts of free air (<0.25 mL) the AUC increased to 0.96 (95% CI 0.89–1.0). At 99% specificity, sensitivity was 81% (13/16) and positive likelihood ratio was 82 (95% CI 27 – 254). Conclusions: An AI algorithm identified pneumoperitoneum on CT scans in a clinical setting with low sensitivity but very high specificity, supporting its role for ruling in pneumoperitoneum. … (more)
- Is Part Of:
- European journal of radiology. Issue 150(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 150(2022)
- Issue Display:
- Volume 150, Issue 150 (2022)
- Year:
- 2022
- Volume:
- 150
- Issue:
- 150
- Issue Sort Value:
- 2022-0150-0150-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05
- Subjects:
- CT -- Artificial Intelligence -- Diagnostic Test Accuracy -- Detection -- Acute Abdomen -- Pneumoperitoneum
ROC Receiver Operating Curve -- AUC Area Under the Curve -- AI Artificial Intelligence
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110216 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21222.xml