A METHOD TO IDENTIFY AND LOCALIZE A SINGLE HOT PARTICLE IN THE LUNGS USING AN ARRAY OF HIGH-PURITY GERMANIUM DETECTORS FOR IMPROVED ESTIMATE OF THE DEPOSITED ACTIVITY. Issue 1 (19th January 2022)
- Record Type:
- Journal Article
- Title:
- A METHOD TO IDENTIFY AND LOCALIZE A SINGLE HOT PARTICLE IN THE LUNGS USING AN ARRAY OF HIGH-PURITY GERMANIUM DETECTORS FOR IMPROVED ESTIMATE OF THE DEPOSITED ACTIVITY. Issue 1 (19th January 2022)
- Main Title:
- A METHOD TO IDENTIFY AND LOCALIZE A SINGLE HOT PARTICLE IN THE LUNGS USING AN ARRAY OF HIGH-PURITY GERMANIUM DETECTORS FOR IMPROVED ESTIMATE OF THE DEPOSITED ACTIVITY
- Authors:
- Aviv, O
Epstein, L
Fried, Y
Spitz, H B
Shonkor, S
Epstein, D
Naim, A
Yungrais, Z
Datz, H - Abstract:
- Abstract: A new method has been developed to identify and localize a single hot particle in the lungs using an array of four high-purity germanium detectors. The method is based upon calculating a set of three count rate ratios (generated by each individual detector in the array) that are evaluated in sequence to designate whether the measured deposition can be associated with a hot particle rather than the default assumption of a uniform activity distribution. Identification and localization of the hot particle are determined from a single in vivo measurement in which detectors are positioned above and below the thorax. The method was tested using an anthropomorphic thorax phantom in which point sources of 241 Am, 137 Cs and 60 Co were individually inserted in the lungs at 15 different locations and were measured using a scanning bed whole-body counter. Depending upon source location and photon energy, a bias of −35% up to +76% could be introduced by falsely assuming a uniform activity distribution in the lungs. This bias would directly translate to an erroneous dose estimate to the lungs. It was demonstrated that by using the appropriate detector efficiencies for the single hot particle, the bias associated with the activity determination is reduced to <10% and ~2% in average.
- Is Part Of:
- Radiation protection dosimetry. Volume 198:Issue 1/2(2022)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 198:Issue 1/2(2022)
- Issue Display:
- Volume 198, Issue 1/2 (2022)
- Year:
- 2022
- Volume:
- 198
- Issue:
- 1/2
- Issue Sort Value:
- 2022-0198-NaN-0000
- Page Start:
- 62
- Page End:
- 73
- Publication Date:
- 2022-01-19
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncab187 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21193.xml