The effect of an air purifier on aerosol generation measurements during clinical motility testing. Issue 4 (2nd August 2021)
- Record Type:
- Journal Article
- Title:
- The effect of an air purifier on aerosol generation measurements during clinical motility testing. Issue 4 (2nd August 2021)
- Main Title:
- The effect of an air purifier on aerosol generation measurements during clinical motility testing
- Authors:
- Verbeure, Wout
Geeraerts, Annelies
Huang, I‐Hsuan
Timmermans, Lien
Tóth, Joran
Geysen, Hannelore
Cools, Louise
Carbone, Florencia
Schol, Jolien
Devriese, Herman
Haesaerts, Rico
Mori, Hideki
Vanuytsel, Tim
Tack, Jan - Abstract:
- Abstract: Background: Aerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high‐resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned. Methods: Patients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair ® II Particle Counter to obtain data about different particles sizes: 0.3; 0.5; 1.0; 3.0; 5.0; and 10.0 µm. Measurements were done immediately before the placement and the removal of the HRM catheter, and one and 5 min after. A portable air purifier with high‐efficiency particle air filters was installed in the hospital room. Key Results: Thirteen patients underwent a manometry examination. The amount of 0.3 µm‐sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min. Conclusions & Interferences: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during aAbstract: Background: Aerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high‐resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned. Methods: Patients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair ® II Particle Counter to obtain data about different particles sizes: 0.3; 0.5; 1.0; 3.0; 5.0; and 10.0 µm. Measurements were done immediately before the placement and the removal of the HRM catheter, and one and 5 min after. A portable air purifier with high‐efficiency particle air filters was installed in the hospital room. Key Results: Thirteen patients underwent a manometry examination. The amount of 0.3 µm‐sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min. Conclusions & Interferences: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during a clinical investigation. … (more)
- Is Part Of:
- Neurogastroenterology & motility. Volume 34:Issue 4(2022)
- Journal:
- Neurogastroenterology & motility
- Issue:
- Volume 34:Issue 4(2022)
- Issue Display:
- Volume 34, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2022-0034-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-08-02
- Subjects:
- aerosol -- air purifier -- COVID19 -- nasogastric intubation
Gastrointestinal system -- Motility -- Periodicals
Gastrointestinal system -- Innervation -- Periodicals
616.33 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=nmo ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2982 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/nmo.14227 ↗
- Languages:
- English
- ISSNs:
- 1350-1925
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.371450
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21205.xml