Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial. Issue 3 (March 2022)
- Main Title:
- Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial
- Authors:
- Kariyawasam, Dulanjalee
Morin, Carole
Casteels, Kristina
Le Tallec, Claire
Sfez, Annie
Godot, Cécile
Huneker, Erik
Garrec, Nathalie
Benhamou, Pierre-Yves
Polak, Michel
Charpentier, Guillaume
Franc, Sylvia
Beltrand, Jacques - Abstract:
- Summary: Background: Time in range (TIR) goals are rarely met in children with type 1 diabetes, except at the cost of increased hypoglycaemia episodes. Our objective was to evaluate the safety and efficiency of the Diabeloop DBL4K (Diabeloop, Grenoble, France) hybrid closed-loop system in prepubescent children. Methods: We did a multicentre, open-label, randomised, controlled, non-inferiority, two-session crossover study in the paediatric endocrinology departments of three university hospitals in France and Belgium. Eligible participants were aged 6–12 years with type 1 diabetes for at least 1 year, glycated haemoglobin A1C 9% (75 mmol/mol) or less, and insulin pump treatment for at least 3 months. Participants were randomly assigned (1:1) to a closed-loop device or sensor-augmented pump (open loop) therapy. Randomisation was by a permuted block randomisation scheme, using an interactive web-based response system, and was stratified on centre (block size 6). The assessed closed-loop device, the Diabeloop for Kids DBL4K hybrid closed-loop system, is an automated blood glucose regulation system composed of a handset, insulin pump, and continuous glucose monitor. The open-loop system is defined as a sensor-augmented pump therapy composed of the usual insulin pump used by the patient and a continuous glucose monitor. A 72-h in-patient period was followed by a 6-week home phase. After a 1-week washout period, the participants crossed over to the other device. The primary outcome,Summary: Background: Time in range (TIR) goals are rarely met in children with type 1 diabetes, except at the cost of increased hypoglycaemia episodes. Our objective was to evaluate the safety and efficiency of the Diabeloop DBL4K (Diabeloop, Grenoble, France) hybrid closed-loop system in prepubescent children. Methods: We did a multicentre, open-label, randomised, controlled, non-inferiority, two-session crossover study in the paediatric endocrinology departments of three university hospitals in France and Belgium. Eligible participants were aged 6–12 years with type 1 diabetes for at least 1 year, glycated haemoglobin A1C 9% (75 mmol/mol) or less, and insulin pump treatment for at least 3 months. Participants were randomly assigned (1:1) to a closed-loop device or sensor-augmented pump (open loop) therapy. Randomisation was by a permuted block randomisation scheme, using an interactive web-based response system, and was stratified on centre (block size 6). The assessed closed-loop device, the Diabeloop for Kids DBL4K hybrid closed-loop system, is an automated blood glucose regulation system composed of a handset, insulin pump, and continuous glucose monitor. The open-loop system is defined as a sensor-augmented pump therapy composed of the usual insulin pump used by the patient and a continuous glucose monitor. A 72-h in-patient period was followed by a 6-week home phase. After a 1-week washout period, the participants crossed over to the other device. The primary outcome, assessed in the intention-to-treat population, was the mean proportion of time spent in hypoglycaemia (3·9 mmol/L [<70 mg/dL]) during the hospital phase, with a non-inferiority margin of –2·5% (absolute value). Safety was assessed in the intention-to-treat population on a per-protocol basis. This study was registered with ClinicalTrials.gov, NCT03671915. Findings: Between May 6 and Dec 23, 2019, we included 21 participants (closed loop then open loop, n=10; open loop then closed loop, n=11). The proportion of time spent in hypoglycaemia was significantly lower with the closed-loop system than the open-loop system in both groups (2·04% [95% CI 0·44 to 3·64] vs 7·06% [5·46 to 8·66]; non-inferiority one-sided p<0·0001). No severe ketoacidosis, nor severe hyoglycaemic events or fatal adverse events occurred. All 25 adverse events (18 with the closed-loop system, seven with the open-loop system) were related to the treatment. Interpretation: The closed-loop Diabeloop system decreased hypoglycaemic episodes and provided good metabolic control in prepubescent children with type 1 diabetes, under real-life conditions. This finding supports the safe use of closed-loop technology in this paediatric population. Funding: Diabeloop. Translation: For the French translation of the abstract see Supplementary Materials section. … (more)
- Is Part Of:
- Lancet. Volume 4:Issue 3(2022)
- Journal:
- Lancet
- Issue:
- Volume 4:Issue 3(2022)
- Issue Display:
- Volume 4, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 4
- Issue:
- 3
- Issue Sort Value:
- 2022-0004-0003-0000
- Page Start:
- e158
- Page End:
- e168
- Publication Date:
- 2022-03
- Subjects:
- Medical care -- Data processing -- Periodicals
Medical care -- Information technology -- Periodicals
Medical informatics -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.thelancet.com/journals/landig/home ↗ - DOI:
- 10.1016/S2589-7500(21)00271-5 ↗
- Languages:
- English
- ISSNs:
- 2589-7500
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21128.xml