Interobserver reproducibility of the offline measurement of fetal head biometry using 3D volume datasets. (16th November 2010)
- Record Type:
- Journal Article
- Title:
- Interobserver reproducibility of the offline measurement of fetal head biometry using 3D volume datasets. (16th November 2010)
- Main Title:
- Interobserver reproducibility of the offline measurement of fetal head biometry using 3D volume datasets
- Authors:
- Salman, MSMA
Mousa, H
Twining, P
Bugg, GJ - Abstract:
- Abstract : Aim: To assess interobserver reproducibility of the offline measurement of fetal head biometry of the 3D volume datasets and to compare them with measurement taken during the real time 2D scan. Methods: 79 3D volume datasets of fetal head were obtained at the time of the scan. 27 were normal, 52 had abnormalities. Offline analysis of them were carried out by three independent fetal medicine experts (E1, E2 and E2) using 4D view software. Measurements of the biparietal diameter (BPD), head circumference (HC), posterior horn of the lateral ventricle (Vp) and transcerebellar diameter (TCD) were compared between examiners and to 2D measurements recorded in patient record. All examiners were blinded to history and patient details. Results: The intraclass co-efficient for data analysis demonstrated a high level of measurement reproducibility between 2D and 3D E1, 3D E2 and 3D E3 with values greater than 0.9 throughout. Bland–Altman plots showed good levels of agreement between 2D and all three 3D observers. The mean percentage differences for the prespecified parameters are 0.3%, 0.7%, 1% and 1.1% for BPD, HC, Vp and TCD respectively. Conclusion: Offline measurement of fetal head biometry using 3D volume dataset is a reliable and reproducible method and correlates well with real time 2D ultrasound. Further work is required to assess the potential use of offline 3D volume dataset analysis as a teaching aid in the measurement of fetal biometry and to examine brainAbstract : Aim: To assess interobserver reproducibility of the offline measurement of fetal head biometry of the 3D volume datasets and to compare them with measurement taken during the real time 2D scan. Methods: 79 3D volume datasets of fetal head were obtained at the time of the scan. 27 were normal, 52 had abnormalities. Offline analysis of them were carried out by three independent fetal medicine experts (E1, E2 and E2) using 4D view software. Measurements of the biparietal diameter (BPD), head circumference (HC), posterior horn of the lateral ventricle (Vp) and transcerebellar diameter (TCD) were compared between examiners and to 2D measurements recorded in patient record. All examiners were blinded to history and patient details. Results: The intraclass co-efficient for data analysis demonstrated a high level of measurement reproducibility between 2D and 3D E1, 3D E2 and 3D E3 with values greater than 0.9 throughout. Bland–Altman plots showed good levels of agreement between 2D and all three 3D observers. The mean percentage differences for the prespecified parameters are 0.3%, 0.7%, 1% and 1.1% for BPD, HC, Vp and TCD respectively. Conclusion: Offline measurement of fetal head biometry using 3D volume dataset is a reliable and reproducible method and correlates well with real time 2D ultrasound. Further work is required to assess the potential use of offline 3D volume dataset analysis as a teaching aid in the measurement of fetal biometry and to examine brain abnormalities. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 95(2010)Supplement 1
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 95(2010)Supplement 1
- Issue Display:
- Volume 95, Issue 1 (2010)
- Year:
- 2010
- Volume:
- 95
- Issue:
- 1
- Issue Sort Value:
- 2010-0095-0001-0000
- Page Start:
- Fa13
- Page End:
- Fa13
- Publication Date:
- 2010-11-16
- Subjects:
- Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/adc.2010.189746.6 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21127.xml