Evaluation of the accuracy of dose delivery in stereotactic radiotherapy using the Velocity commercial software. (March 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of the accuracy of dose delivery in stereotactic radiotherapy using the Velocity commercial software. (March 2022)
- Main Title:
- Evaluation of the accuracy of dose delivery in stereotactic radiotherapy using the Velocity commercial software
- Authors:
- Czajkowski, Paweł
Piotrowski, Tomasz - Abstract:
- Highlights: The methodology of creating registered CT to control RT process was shown. Despite the volume changes or displacement, the GTV/ITV were within the PTV. The differences between the planned and delivered doses were not significant. Abstract: Purpose: The purpose of this study was to evaluate the accuracy of dose delivery during stereotactic radiotherapy of the lung (SBRT) and brain (SRT) tumours by registered CT (rCT) images obtained from CT used for planning (pCT) and cone-beam CT (CBCT). Methods: The study is based on two groups of patients (10 patients each) undergoing SBRT and SRT. To assess the correctness of the propagation of the GTV (brain group) and ITV (lung group) contours, the volumes calculated on the pCT and rCT studies were analysed. The Dice-Sørensen similarity coefficient (DSC) was used to check the variability in the position of GTV/ITV observed between pCT and rCT. The dose recalculated on rCT was compared with the dose from pCT. Result: GTV and ITV determined on pCT and rCT studies did not differ statistically (p = 0.770 for ITV and p = 0.086 for GTV). DSC obtained for the lung group was statistically smaller than that for the brain group (p < 0.001). Differences between doses obtained for 99% of the ITV/GTV on pCT and rCT studies were within ±10% and did not exceed the clinically acceptable tolerance. Conclusion: The observed changes in the volume (ITV/GTV) were within the area of the original PTV volume. The differences between the planned andHighlights: The methodology of creating registered CT to control RT process was shown. Despite the volume changes or displacement, the GTV/ITV were within the PTV. The differences between the planned and delivered doses were not significant. Abstract: Purpose: The purpose of this study was to evaluate the accuracy of dose delivery during stereotactic radiotherapy of the lung (SBRT) and brain (SRT) tumours by registered CT (rCT) images obtained from CT used for planning (pCT) and cone-beam CT (CBCT). Methods: The study is based on two groups of patients (10 patients each) undergoing SBRT and SRT. To assess the correctness of the propagation of the GTV (brain group) and ITV (lung group) contours, the volumes calculated on the pCT and rCT studies were analysed. The Dice-Sørensen similarity coefficient (DSC) was used to check the variability in the position of GTV/ITV observed between pCT and rCT. The dose recalculated on rCT was compared with the dose from pCT. Result: GTV and ITV determined on pCT and rCT studies did not differ statistically (p = 0.770 for ITV and p = 0.086 for GTV). DSC obtained for the lung group was statistically smaller than that for the brain group (p < 0.001). Differences between doses obtained for 99% of the ITV/GTV on pCT and rCT studies were within ±10% and did not exceed the clinically acceptable tolerance. Conclusion: The observed changes in the volume (ITV/GTV) were within the area of the original PTV volume. The differences between the planned and delivered doses in the ITV/GTV were not clinically significant. … (more)
- Is Part Of:
- Physica medica. Volume 95(2022)
- Journal:
- Physica medica
- Issue:
- Volume 95(2022)
- Issue Display:
- Volume 95, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 95
- Issue:
- 2022
- Issue Sort Value:
- 2022-0095-2022-0000
- Page Start:
- 133
- Page End:
- 139
- Publication Date:
- 2022-03
- Subjects:
- Deformable image registration -- Stereotactic radiation therapy -- Dose guided radiation therapy -- Image guided radiation therapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.02.005 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21141.xml