Validity of four commercially available metabolic carts for assessing resting metabolic rate and respiratory exchange ratio in non-ventilated humans. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Validity of four commercially available metabolic carts for assessing resting metabolic rate and respiratory exchange ratio in non-ventilated humans. Issue 3 (March 2022)
- Main Title:
- Validity of four commercially available metabolic carts for assessing resting metabolic rate and respiratory exchange ratio in non-ventilated humans
- Authors:
- Alcantara, J.M.A.
Galgani, J.E.
Jurado-Fasoli, L.
Dote-Montero, M.
Merchan-Ramirez, E.
Ravussin, E.
Ruiz, J.R.
Sanchez-Delgado, G. - Abstract:
- Summary: Background & aims: The validity of most commercially available metabolic cart is mostly unknown. Thus, we aimed to determine the accuracy, precision, within-subject reproducibility, and concordance of RMR and RER measured by four commercially available metabolic carts [Cosmed Q-NRG, Vyaire Vyntus CPX, Maastricht Instruments Omnical, and Medgraphics Ultima CardiO2 ]. Further, we studied whether a previously proposed simulation-based post-calorimetric calibration of cart readouts [individual calibration control evaluation (ICcE)] modify the RMR and RER reproducibility and concordance. Methods: Three experiments simulating different RMR and RER by controlled pure gas (N2 and CO2 ) infusions were conducted on 5 non-consecutive days. Moreover, 30-min methanol burns were performed on 3 non-consecutive days. Lastly, the RMR and RER of 29 young non-ventilated adults (11 women; 25 ± 4 years-old; BMI: 24.1 ± 3.2 kg/m 2 ) were assessed twice using each instrument, 24 hours apart, under standardized conditions. Results: The Omnical presented the lowest measurement error for RER (Omnical = 1.7 ± 0.9%; Vyntus = 4.5 ± 2.0%; Q-NRG = 6.6 ± 1.9%; Ultima = 6.8 ± 6.5%) and EE (Omnical = 1.5 ± 0.5%; Q-NRG = 2.5 ± 1.3%; Ultima = 10.7 ± 11.0%; Vyntus = 13.8 ± 5.0%) in all in vitro experiments (controlled pure gas infusions and methanol burns). In humans, the 4 metabolic carts provided discordant RMR and RER estimations (all P < 0.001). No differences were detected in RMR within-subjectSummary: Background & aims: The validity of most commercially available metabolic cart is mostly unknown. Thus, we aimed to determine the accuracy, precision, within-subject reproducibility, and concordance of RMR and RER measured by four commercially available metabolic carts [Cosmed Q-NRG, Vyaire Vyntus CPX, Maastricht Instruments Omnical, and Medgraphics Ultima CardiO2 ]. Further, we studied whether a previously proposed simulation-based post-calorimetric calibration of cart readouts [individual calibration control evaluation (ICcE)] modify the RMR and RER reproducibility and concordance. Methods: Three experiments simulating different RMR and RER by controlled pure gas (N2 and CO2 ) infusions were conducted on 5 non-consecutive days. Moreover, 30-min methanol burns were performed on 3 non-consecutive days. Lastly, the RMR and RER of 29 young non-ventilated adults (11 women; 25 ± 4 years-old; BMI: 24.1 ± 3.2 kg/m 2 ) were assessed twice using each instrument, 24 hours apart, under standardized conditions. Results: The Omnical presented the lowest measurement error for RER (Omnical = 1.7 ± 0.9%; Vyntus = 4.5 ± 2.0%; Q-NRG = 6.6 ± 1.9%; Ultima = 6.8 ± 6.5%) and EE (Omnical = 1.5 ± 0.5%; Q-NRG = 2.5 ± 1.3%; Ultima = 10.7 ± 11.0%; Vyntus = 13.8 ± 5.0%) in all in vitro experiments (controlled pure gas infusions and methanol burns). In humans, the 4 metabolic carts provided discordant RMR and RER estimations (all P < 0.001). No differences were detected in RMR within-subject reproducibility (P = 0.058; Q-NRG inter-day coefficient of variance = 3.6 ± 2.5%; Omnical = 4.8 ± 3.5%; Vyntus = 5.0 ± 5.6%; Ultima = 5.7 ± 4.6%), although the Ultima CardiO2 provided larger RER inter-day differences (4.6 ± 3.5%) than the others carts (P = 0.001; Omnical = 1.9 ± 1.7%; Vyntus = 2.1 ± 1.3%; Q-NRG = 2.4 ± 2.1%). The ICcE procedure did not modify the RMR or RER concordance and did not reduce the inter-day differences in any of the carts. Conclusions: The 4 metabolic carts provided discordant measurements of RMR and RER. Overall, the Omnical provides more accurate and precise estimations of RMR and RER than the Q-NRG, Vyntus and Ultima CardiO2, and might be considered the best for assessing RMR and RER in non-ventilated humans. Finally, our results do not support the use of an ICcE procedure. … (more)
- Is Part Of:
- Clinical nutrition. Volume 41:Issue 3(2022)
- Journal:
- Clinical nutrition
- Issue:
- Volume 41:Issue 3(2022)
- Issue Display:
- Volume 41, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2022-0041-0003-0000
- Page Start:
- 746
- Page End:
- 754
- Publication Date:
- 2022-03
- Subjects:
- Indirect calorimetry -- Reliability -- Basal metabolic rate
Critically ill -- Nutrition -- Periodicals
Diet therapy -- Periodicals
Parenteral feeding -- Periodicals
Enteral feeding -- Periodicals
Enteral Nutrition -- Periodicals
Parenteral Nutrition -- Periodicals
Metabolism -- Periodicals
Diétothérapie -- Périodiques
Alimentation parentérale -- Périodiques
Alimentation entérale -- Périodiques
Nutrition -- Périodiques
Diet therapy
Enteral feeding
Nutrition
Parenteral feeding
Electronic journals
Periodicals
Electronic journals
615.854 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02615614 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clnu.2022.01.031 ↗
- Languages:
- English
- ISSNs:
- 0261-5614
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.314500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21135.xml