Degradation of internal fixation materials based on antibacterial and absorbable silk containing different gentamicin concentrations. (July 2022)
- Record Type:
- Journal Article
- Title:
- Degradation of internal fixation materials based on antibacterial and absorbable silk containing different gentamicin concentrations. (July 2022)
- Main Title:
- Degradation of internal fixation materials based on antibacterial and absorbable silk containing different gentamicin concentrations
- Authors:
- Shi, Chenglong
Liao, Xuqiang
Pu, Xiaobing
Li, Xiushi
Wu, Ruihui
Deng, Donghai
Zhou, Yunfei
Huang, Xingqiu - Abstract:
- Adding gentamicin to silk fibroin enhances both the antibacterial performance and degradation rate of silk-based materials. The increased material degradation rate can affect the strength of early internal fixation, resulting in internal fixation failure. This study sought to adjust the gentamicin concentration to control the material degradation rate, thereby better meeting clinical application requirements. The in vitro degradation, water absorption rate, and expansion rate of silk-based materials containing different gentamicin concentrations were studied. A gentamicin-loaded silk-based screw was implanted into the femurs of New Zealand rabbits. Micro-computed tomography was used to measure the screw diameter, which was then used to calculate the degradation rate. The specimens were stained with hematoxylin and eosin and Masson's trichrome. The in vitro results revealed increasing material degradation rates with increasing gentamicin concentration but no significant differences in water absorption rates with different gentamicin concentrations. The degradation rates of gentamicin-loaded (4 mg/g) silk-based rod-like materials were approximately 11.08% at three months in vitro and 9.4% in the animal experiment. The time for complete degradation was predicted from the fitting curve to be approximately 16 months. No inflammatory hyperplasia was observed in bone or soft tissue. The degradation and biocompatibility of the material containing 4 mg/g gentamicin meet clinicalAdding gentamicin to silk fibroin enhances both the antibacterial performance and degradation rate of silk-based materials. The increased material degradation rate can affect the strength of early internal fixation, resulting in internal fixation failure. This study sought to adjust the gentamicin concentration to control the material degradation rate, thereby better meeting clinical application requirements. The in vitro degradation, water absorption rate, and expansion rate of silk-based materials containing different gentamicin concentrations were studied. A gentamicin-loaded silk-based screw was implanted into the femurs of New Zealand rabbits. Micro-computed tomography was used to measure the screw diameter, which was then used to calculate the degradation rate. The specimens were stained with hematoxylin and eosin and Masson's trichrome. The in vitro results revealed increasing material degradation rates with increasing gentamicin concentration but no significant differences in water absorption rates with different gentamicin concentrations. The degradation rates of gentamicin-loaded (4 mg/g) silk-based rod-like materials were approximately 11.08% at three months in vitro and 9.4% in the animal experiment. The time for complete degradation was predicted from the fitting curve to be approximately 16 months. No inflammatory hyperplasia was observed in bone or soft tissue. The degradation and biocompatibility of the material containing 4 mg/g gentamicin meet clinical application requirements, and previous experimental results demonstrate good antibacterial performance of materials containing this gentamicin concentration. … (more)
- Is Part Of:
- Journal of biomaterials applications. Volume 37:Number 1(2022)
- Journal:
- Journal of biomaterials applications
- Issue:
- Volume 37:Number 1(2022)
- Issue Display:
- Volume 37, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2022-0037-0001-0000
- Page Start:
- 33
- Page End:
- 39
- Publication Date:
- 2022-07
- Subjects:
- silk -- gentamicin -- degradation -- biocompatibility -- antibacterial -- fixation devices
Biomedical engineering -- Periodicals
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://jba.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/08853282221084959 ↗
- Languages:
- English
- ISSNs:
- 0885-3282
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21141.xml