Efficacy of Intraventricular Sponge Placement to Capture Debris in Aortic Valve Replacement. Issue 3 (May 2022)
- Record Type:
- Journal Article
- Title:
- Efficacy of Intraventricular Sponge Placement to Capture Debris in Aortic Valve Replacement. Issue 3 (May 2022)
- Main Title:
- Efficacy of Intraventricular Sponge Placement to Capture Debris in Aortic Valve Replacement
- Authors:
- Purrman, Kyle C.
Ndikumana, Eric
Amirjamshidi, Hossein
Syposs, Chauncey
Vidovich, Courtney
Boyce, Brendan
Knight, Peter - Abstract:
- Objective: Surgical aortic valve replacement (SAVR) carries the known risk of shedding debris into the left ventricle during valve leaflet excision and annulus debridement. Embolization of this debris may have devastating effects for the patient. Although surgeons have developed methods to mitigate this risk, no data exist as to their efficacy. Herein, we present the first study that evaluates the efficacy of a technique for capturing debris during SAVR.Methods: Our group conducted a prospective case series of 20 patients who underwent SAVR using the insertion of an intraventricular surgical sponge prior to valve leaflet excision and annulus debridement to capture debris. Surgical sponges were grossly, radiographically, and histologically examined for the presence of cellular and acellular debris to determine the efficacy of this technique.Results: Of the 20 surgical sponges analyzed, 15 specimens (75%) registered positivity for cellular and/or acellular debris. Seven sponges (35%) were grossly positive, 15 sponges (75%) were radiographically positive, and 4 sponges (20%) were histologically positive for calcified debris on examination.Conclusions: This is one of the few studies to objectively evaluate a method used to capture debris in SAVR procedures. Our results demonstrate a high frequency of debris captured within intraventricular surgical sponges and confirms the efficacy of this technique. While these data are promising, numerous additional approaches exist to captureObjective: Surgical aortic valve replacement (SAVR) carries the known risk of shedding debris into the left ventricle during valve leaflet excision and annulus debridement. Embolization of this debris may have devastating effects for the patient. Although surgeons have developed methods to mitigate this risk, no data exist as to their efficacy. Herein, we present the first study that evaluates the efficacy of a technique for capturing debris during SAVR.Methods: Our group conducted a prospective case series of 20 patients who underwent SAVR using the insertion of an intraventricular surgical sponge prior to valve leaflet excision and annulus debridement to capture debris. Surgical sponges were grossly, radiographically, and histologically examined for the presence of cellular and acellular debris to determine the efficacy of this technique.Results: Of the 20 surgical sponges analyzed, 15 specimens (75%) registered positivity for cellular and/or acellular debris. Seven sponges (35%) were grossly positive, 15 sponges (75%) were radiographically positive, and 4 sponges (20%) were histologically positive for calcified debris on examination.Conclusions: This is one of the few studies to objectively evaluate a method used to capture debris in SAVR procedures. Our results demonstrate a high frequency of debris captured within intraventricular surgical sponges and confirms the efficacy of this technique. While these data are promising, numerous additional approaches exist to capture debris, and a best practice standard should exist across the specialty. In addition, this study does not address the clinical outcomes associated with this technique. To these ends, additional data and multicenter collaboration are required. … (more)
- Is Part Of:
- Innovations. Volume 17:Issue 3(2022)
- Journal:
- Innovations
- Issue:
- Volume 17:Issue 3(2022)
- Issue Display:
- Volume 17, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2022-0017-0003-0000
- Page Start:
- 217
- Page End:
- 222
- Publication Date:
- 2022-05
- Subjects:
- aortic valve replacement -- surgical sponge -- debris
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/15569845221095876 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21120.xml