Minimum 10-year follow-up of micro-arc oxidation coating on a cementless grit-blasted tapered-wedge stem of total hip arthroplasty: a multicentre study. Issue 4 (July 2022)
- Record Type:
- Journal Article
- Title:
- Minimum 10-year follow-up of micro-arc oxidation coating on a cementless grit-blasted tapered-wedge stem of total hip arthroplasty: a multicentre study. Issue 4 (July 2022)
- Main Title:
- Minimum 10-year follow-up of micro-arc oxidation coating on a cementless grit-blasted tapered-wedge stem of total hip arthroplasty: a multicentre study
- Authors:
- Lim, Young-Wook
Song, Joo-Hyoun
Kwon, Soon-Yong
Kim, Yong-Sik
Byun, Young-Seol
Lee, Se-Won - Abstract:
- Background: Recently, a femoral stem treated with grit-blasting and micro-arc oxidation (MAO) coating has commercialised but medium-term follow-up studies are lacking. The aim of this study was to report the outcome of a grit-blasted and MAO-coated femoral component designed as a straight, double-wedged, tapered stem with a rectangular cross-section with minimum 10 years follow-up. Methods: Between March 2006 and December 2008, 309 primary total hip arthroplasties using a grit-blasted and MAO-coated femoral component were performed by 3 experienced hip surgeons in 3 hospitals. At minimum 10 years after index THA, 299 hips were living, 10 hips were deceased, and 65 hips were lost to follow-up or had a follow-up period <10 years. Finally, 234 hips were enrolled in this study. Results: Mean duration of clinical follow-up was 129.6 months. The mean Harris Hip Score was improved from 46.9 to 88.4 at the final follow-up. 4 hips were revised for 2 aseptic femoral loosening, 1 aseptic acetabular cup loosening and 1 late infection. 3 hips were revised for a periprosthetic femoral fracture requiring a femoral component revision. The average time to revision was 51.6 (range 0–148) months. Kaplan-Meier survivorship analysis with an end point of revision for any reason demonstrated a survival rate of 97.4% at 10 years. Survival was 98.7% with revision for aseptic loosening as the endpoint. Conclusions: The outcomes of a cementless grit-blasted and MAO-coated tapered-wedge stem of THABackground: Recently, a femoral stem treated with grit-blasting and micro-arc oxidation (MAO) coating has commercialised but medium-term follow-up studies are lacking. The aim of this study was to report the outcome of a grit-blasted and MAO-coated femoral component designed as a straight, double-wedged, tapered stem with a rectangular cross-section with minimum 10 years follow-up. Methods: Between March 2006 and December 2008, 309 primary total hip arthroplasties using a grit-blasted and MAO-coated femoral component were performed by 3 experienced hip surgeons in 3 hospitals. At minimum 10 years after index THA, 299 hips were living, 10 hips were deceased, and 65 hips were lost to follow-up or had a follow-up period <10 years. Finally, 234 hips were enrolled in this study. Results: Mean duration of clinical follow-up was 129.6 months. The mean Harris Hip Score was improved from 46.9 to 88.4 at the final follow-up. 4 hips were revised for 2 aseptic femoral loosening, 1 aseptic acetabular cup loosening and 1 late infection. 3 hips were revised for a periprosthetic femoral fracture requiring a femoral component revision. The average time to revision was 51.6 (range 0–148) months. Kaplan-Meier survivorship analysis with an end point of revision for any reason demonstrated a survival rate of 97.4% at 10 years. Survival was 98.7% with revision for aseptic loosening as the endpoint. Conclusions: The outcomes of a cementless grit-blasted and MAO-coated tapered-wedge stem of THA were excellent to satisfactory after a follow-up of at least 10 years. … (more)
- Is Part Of:
- Hip international. Volume 32:Issue 4(2022)
- Journal:
- Hip international
- Issue:
- Volume 32:Issue 4(2022)
- Issue Display:
- Volume 32, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2022-0032-0004-0000
- Page Start:
- 501
- Page End:
- 509
- Publication Date:
- 2022-07
- Subjects:
- Outcome -- total hip arthroplasty -- total joint arthroplasty -- uncemented
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.1177/1120700020977465 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21112.xml