E0150 High frequency of peri-strut low intensity area assessed by optical coherence tomography after polymer-based sirolimus-eluting stents implantation in porcine model. (17th November 2010)
- Record Type:
- Journal Article
- Title:
- E0150 High frequency of peri-strut low intensity area assessed by optical coherence tomography after polymer-based sirolimus-eluting stents implantation in porcine model. (17th November 2010)
- Main Title:
- E0150 High frequency of peri-strut low intensity area assessed by optical coherence tomography after polymer-based sirolimus-eluting stents implantation in porcine model
- Authors:
- Haibo, Jia
Jingbo, Hou
Jian, Wu
Maomao, Zhang
Hai, Qi
Xingtao, Huang
Huiming, Liu
Sining, Hu
Rong, Sun
Shuo, Zhang
Bo, Yu - Abstract:
- Abstract : Objectives: To assess the frequency of peri-strut low intensity area (PLIA) in polymeric and nonpolymeric drug-eluting stents by optical coherence tomography (OCT) in porcine model, to analyse the pathological changes in PLIA. Setting: Previous intravascular ultrasound studies showed that black holes were more commonly seen in sirolimus-eluting stent restenosis. Similar phenomenon (peri-strut low intensity area) was also frequently detected by OCT in DES follow-up. However, it is still largely unknown what triggers this uncommon response. Design and interventions: A total of 18 stents (BMS, n=6; polymer-free PES [PF-PES], n=6 and polymer-based SES [PB-SES], n=6) were implanted in six minipigs and OCT was performed at 28 days after stenting. Stented arteries were harvested after terminal OCT imaging for pathological analysis. PLIA was defined as a region around stent struts with a homogenous lower intensity appearance than surrounding tissue on OCT images without significant signal attenuation behind the area. Results: At 28 days, PLIA was more frequently observed around the PBSES struts compared with PFPES and BMS struts (75% vs 33% vs 12%, respectively, p<0.001). Both in DES and BMS group, stents with PLIA showed significantly greater neointimal thickness than stents without PLIA (0.55±0.23 mm vs 0.13±0.08 mm, p<0.001). Histological results showed the existence of fibrin deposition and small amount of inflammatory cells at the site of PLIA. Conclusions: PBSESAbstract : Objectives: To assess the frequency of peri-strut low intensity area (PLIA) in polymeric and nonpolymeric drug-eluting stents by optical coherence tomography (OCT) in porcine model, to analyse the pathological changes in PLIA. Setting: Previous intravascular ultrasound studies showed that black holes were more commonly seen in sirolimus-eluting stent restenosis. Similar phenomenon (peri-strut low intensity area) was also frequently detected by OCT in DES follow-up. However, it is still largely unknown what triggers this uncommon response. Design and interventions: A total of 18 stents (BMS, n=6; polymer-free PES [PF-PES], n=6 and polymer-based SES [PB-SES], n=6) were implanted in six minipigs and OCT was performed at 28 days after stenting. Stented arteries were harvested after terminal OCT imaging for pathological analysis. PLIA was defined as a region around stent struts with a homogenous lower intensity appearance than surrounding tissue on OCT images without significant signal attenuation behind the area. Results: At 28 days, PLIA was more frequently observed around the PBSES struts compared with PFPES and BMS struts (75% vs 33% vs 12%, respectively, p<0.001). Both in DES and BMS group, stents with PLIA showed significantly greater neointimal thickness than stents without PLIA (0.55±0.23 mm vs 0.13±0.08 mm, p<0.001). Histological results showed the existence of fibrin deposition and small amount of inflammatory cells at the site of PLIA. Conclusions: PBSES showed a higher incidence of PLIA compared with BMS and PFPES. PLIA may be related to fibrin deposition and vessel chronic inflammatory response to stent. … (more)
- Is Part Of:
- Heart. Volume 96(2010)Supplement 3
- Journal:
- Heart
- Issue:
- Volume 96(2010)Supplement 3
- Issue Display:
- Volume 96, Issue 3 (2010)
- Year:
- 2010
- Volume:
- 96
- Issue:
- 3
- Issue Sort Value:
- 2010-0096-0003-0000
- Page Start:
- A48
- Page End:
- A48
- Publication Date:
- 2010-11-17
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2010.208967.150 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21107.xml