E0691 Feasibility and reproducibility of a new semiautomated quantification of left ventricular volumes and ejection fraction in normal adults using real time 3-dimensional echocardiography. (17th November 2010)
- Record Type:
- Journal Article
- Title:
- E0691 Feasibility and reproducibility of a new semiautomated quantification of left ventricular volumes and ejection fraction in normal adults using real time 3-dimensional echocardiography. (17th November 2010)
- Main Title:
- E0691 Feasibility and reproducibility of a new semiautomated quantification of left ventricular volumes and ejection fraction in normal adults using real time 3-dimensional echocardiography
- Authors:
- Yuman, Li
Mingxing, Xie
Xinfang, Wang
Qing, Lv
Li, Yuan
Lan, Jiang
Yue, Song
Ning, Zhang - Abstract:
- Abstract : Objective: We sought to investigate the feasibility and reproducibility of the new semi-automated tool (4DLVQ) quantification of left ventricular (LV) volumes and ejection fraction (EF) compared to standard 3D echo tool (TomTec 4D LV-Analysis) using real time 3-dimensional echocardiography. Methods: Real time 3D echocardiography examinations were performed in 24 volunteers. In the apical 3D full-volumetric images, LV end-diastolic volumes (EDV), end-systolic volumes (ESV) and EF were measured using 4DLVQ and TomTec. The repeatability and agreement of the new method were evaluated compared to TomTec. Results: 1. The analysis time of 4DLVQ was significantly shorter than for TomTec (156.63±33.72 s vs 275.55±50.64 s, p<0.05). 2. There were no significant difference in LVEDV (75.40±16.72 ml vs 71.65±14.81 ml), LVESV (30.25±6.69 ml vs 28.30±6.71 ml) and LVEF (59.65±4.96% vs 60.70±3.51%) between the two methods (p>0.05). 3. LVEDV, LVESV and LVEF measured by 4DLVQ had good correlation with those by TomTec. (r1 =0.715, r2 =0.618 r3 =0.532, respectively, p<0.05 for all). 4. Bland-Altman analysis revealed high agreement in LV volume and EF between 4DLVQ and TomTec, with 95% limits of agreement of −19.8∼27.3 ml, −9.5∼13.4 ml and −9.4∼7.3% for EDV, ESV, and EF respectively. Comparison with TomTec, 4DLVQ showed lower intraobserver and interobserver variabilities, Intra-observer variability of 4DLVQ versus TomTec was 12.29% versus 21.96% for EDV, 16.92% versus 34.35% for ESV,Abstract : Objective: We sought to investigate the feasibility and reproducibility of the new semi-automated tool (4DLVQ) quantification of left ventricular (LV) volumes and ejection fraction (EF) compared to standard 3D echo tool (TomTec 4D LV-Analysis) using real time 3-dimensional echocardiography. Methods: Real time 3D echocardiography examinations were performed in 24 volunteers. In the apical 3D full-volumetric images, LV end-diastolic volumes (EDV), end-systolic volumes (ESV) and EF were measured using 4DLVQ and TomTec. The repeatability and agreement of the new method were evaluated compared to TomTec. Results: 1. The analysis time of 4DLVQ was significantly shorter than for TomTec (156.63±33.72 s vs 275.55±50.64 s, p<0.05). 2. There were no significant difference in LVEDV (75.40±16.72 ml vs 71.65±14.81 ml), LVESV (30.25±6.69 ml vs 28.30±6.71 ml) and LVEF (59.65±4.96% vs 60.70±3.51%) between the two methods (p>0.05). 3. LVEDV, LVESV and LVEF measured by 4DLVQ had good correlation with those by TomTec. (r1 =0.715, r2 =0.618 r3 =0.532, respectively, p<0.05 for all). 4. Bland-Altman analysis revealed high agreement in LV volume and EF between 4DLVQ and TomTec, with 95% limits of agreement of −19.8∼27.3 ml, −9.5∼13.4 ml and −9.4∼7.3% for EDV, ESV, and EF respectively. Comparison with TomTec, 4DLVQ showed lower intraobserver and interobserver variabilities, Intra-observer variability of 4DLVQ versus TomTec was 12.29% versus 21.96% for EDV, 16.92% versus 34.35% for ESV, and 6.50% versus 7.24% for EF. Inter-observer variability of 4DLVQ versus TomTec was 9.84% versus 18.13% for EDV, 10.47% versus 25.12% for ESV, and 6.50% versus 6.72% for EF. In comparison with TomTec, 4DLVQ showed higher intra-class correlation coefficient. Conclusions: 4DLVQ is a novel, simple, feasible and reproducible tool for LV volumes and EF. … (more)
- Is Part Of:
- Heart. Volume 96(2010)Supplement 3
- Journal:
- Heart
- Issue:
- Volume 96(2010)Supplement 3
- Issue Display:
- Volume 96, Issue 3 (2010)
- Year:
- 2010
- Volume:
- 96
- Issue:
- 3
- Issue Sort Value:
- 2010-0096-0003-0000
- Page Start:
- A214
- Page End:
- A214
- Publication Date:
- 2010-11-17
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2010.208967.691 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21106.xml