Impact of geometric distortion on dose deviation for photon and proton treatment plans. Issue 3 (2nd February 2022)
- Record Type:
- Journal Article
- Title:
- Impact of geometric distortion on dose deviation for photon and proton treatment plans. Issue 3 (2nd February 2022)
- Main Title:
- Impact of geometric distortion on dose deviation for photon and proton treatment plans
- Authors:
- Yan, Yue
Yang, Jinzhong
Li, Yuting
Ding, Yao
Kadbi, Mo
Wang, Jihong - Abstract:
- Abstract: We investigated the dose deviation related to geometric distortion and dose gradient on magnetic resonance‐only treatment planning for intensity‐modulated radiation therapy and proton therapy. The residual geometric distortion of two different magnetic resonance imaging (MRI) sequences (A ) and (B ) was applied in the computed tomography image and the structure set of each patient through a polynomial MRI geometric distortion model to simulate MRI‐based treatment planning. A 3D histogram was generated to specify the relationship of dose deviation to geometric distortion and dose gradient. When the dose gradient (Gd ) approached zero, the maximum dose deviation reached 1.64% and 2.71% for photon plans of sequences A and B, respectively. For proton plans, the maximum dose deviation reached 3.15% and 4.89% for sequences A and B, respectively. When the geometric distortion ( d ) was close to zero, the maximum dose deviation was less than 0.8% for photon and proton plans of both sequences. Under extreme conditions ( d = 2 mm and Gd = 4.5%/mm), the median value of dose deviation reached 3% and 3.49% for photon and proton plans, respectively for sequence A, and 2.93% and 4.55% for photon and proton plans, respectively, for sequence B . We demonstrate that the dose deviation is specific to MRI hardware parameters. Compared to the photon plan, the proton plan is more sensitive to the changes in geometric distortion. For typical clinical MRI geometric distortion ( dAbstract: We investigated the dose deviation related to geometric distortion and dose gradient on magnetic resonance‐only treatment planning for intensity‐modulated radiation therapy and proton therapy. The residual geometric distortion of two different magnetic resonance imaging (MRI) sequences (A ) and (B ) was applied in the computed tomography image and the structure set of each patient through a polynomial MRI geometric distortion model to simulate MRI‐based treatment planning. A 3D histogram was generated to specify the relationship of dose deviation to geometric distortion and dose gradient. When the dose gradient (Gd ) approached zero, the maximum dose deviation reached 1.64% and 2.71% for photon plans of sequences A and B, respectively. For proton plans, the maximum dose deviation reached 3.15% and 4.89% for sequences A and B, respectively. When the geometric distortion ( d ) was close to zero, the maximum dose deviation was less than 0.8% for photon and proton plans of both sequences. Under extreme conditions ( d = 2 mm and Gd = 4.5%/mm), the median value of dose deviation reached 3% and 3.49% for photon and proton plans, respectively for sequence A, and 2.93% and 4.55% for photon and proton plans, respectively, for sequence B . We demonstrate that the dose deviation is specific to MRI hardware parameters. Compared to the photon plan, the proton plan is more sensitive to the changes in geometric distortion. For typical clinical MRI geometric distortion ( d ≤2 mm), the median dose deviation is expected to be within 3% and 5% for photon and proton plans, respectively. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 3(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 3(2022)
- Issue Display:
- Volume 23, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2022-0023-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-02-02
- Subjects:
- geometric distortion -- MRI guided radiation therapy -- proton therapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13517 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21073.xml