Assessment and validation of a novel fast fully automated artificial intelligence left ventricular ejection fraction quantification software. Issue 3 (17th February 2022)
- Record Type:
- Journal Article
- Title:
- Assessment and validation of a novel fast fully automated artificial intelligence left ventricular ejection fraction quantification software. Issue 3 (17th February 2022)
- Main Title:
- Assessment and validation of a novel fast fully automated artificial intelligence left ventricular ejection fraction quantification software
- Authors:
- Samtani, Rajeev
Bienstock, Solomon
Lai, Ashton C.
Liao, Steve
Baber, Usman
Croft, Lori
Stern, Eric
Beerkens, Frans
Ting, Peter
Goldman, Martin E. - Abstract:
- Abstract: Background: Quantification of left ventricular ejection fraction (LVEF) by transthoracic echocardiography (TTE) is operator‐dependent, time‐consuming, and error‐prone. LVivoEF by DIA is a new artificial intelligence (AI) software, which displays the tracking of endocardial borders and rapidly quantifies LVEF. We sought to assess the accuracy of LVivoEF compared to cardiac magnetic resonance imaging (cMRI) as the reference standard and to compare LVivoEF to the standard‐of‐care physician‐measured LVEF (MD‐EF) including studies with ultrasound enhancing agents (UEAs). Methods: In 273 consecutive patients, we compared MD‐EF and AI‐derived LVEF to cMRI. AI‐derived LVEF was obtained from a non‐UEA four‐chamber view without manual correction. Thirty‐one patients were excluded: 25 had interval interventions or incomplete TTE or cMRI studies and six had uninterpretable non‐UEA apical views. Results: In the 242 subjects, the correlation between AI and cMRI was r = .890, similar to MD‐EF and cMRI with r = .891 ( p = 0.48). Of the 126 studies performed with UEAs, the correlation of AI using the unenhanced four‐chamber view was r = .89, similar to MD‐EF with r = .90. In the 116 unenhanced studies, AI correlation was r = .87, similar to MD‐EF with r = .84. From Bland‐Altman analysis, LVivoEF underreported the LVEF with a bias of 3.63 ± 7.40% EF points compared to cMRI while MD‐EF to cMRI had a bias of .33 ± 7.52% ( p = 0.80). Conclusions: Compared to cMRI, LVivoEF canAbstract: Background: Quantification of left ventricular ejection fraction (LVEF) by transthoracic echocardiography (TTE) is operator‐dependent, time‐consuming, and error‐prone. LVivoEF by DIA is a new artificial intelligence (AI) software, which displays the tracking of endocardial borders and rapidly quantifies LVEF. We sought to assess the accuracy of LVivoEF compared to cardiac magnetic resonance imaging (cMRI) as the reference standard and to compare LVivoEF to the standard‐of‐care physician‐measured LVEF (MD‐EF) including studies with ultrasound enhancing agents (UEAs). Methods: In 273 consecutive patients, we compared MD‐EF and AI‐derived LVEF to cMRI. AI‐derived LVEF was obtained from a non‐UEA four‐chamber view without manual correction. Thirty‐one patients were excluded: 25 had interval interventions or incomplete TTE or cMRI studies and six had uninterpretable non‐UEA apical views. Results: In the 242 subjects, the correlation between AI and cMRI was r = .890, similar to MD‐EF and cMRI with r = .891 ( p = 0.48). Of the 126 studies performed with UEAs, the correlation of AI using the unenhanced four‐chamber view was r = .89, similar to MD‐EF with r = .90. In the 116 unenhanced studies, AI correlation was r = .87, similar to MD‐EF with r = .84. From Bland‐Altman analysis, LVivoEF underreported the LVEF with a bias of 3.63 ± 7.40% EF points compared to cMRI while MD‐EF to cMRI had a bias of .33 ± 7.52% ( p = 0.80). Conclusions: Compared to cMRI, LVivoEF can accurately quantify LVEF from a standard apical four‐chamber view without manual correction. Thus, LVivoEF has the ability to improve and expedite LVEF quantification. … (more)
- Is Part Of:
- Echocardiography. Volume 39:Issue 3(2022)
- Journal:
- Echocardiography
- Issue:
- Volume 39:Issue 3(2022)
- Issue Display:
- Volume 39, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2022-0039-0003-0000
- Page Start:
- 473
- Page End:
- 482
- Publication Date:
- 2022-02-17
- Subjects:
- artificial intelligence -- cardiac MRI -- echocardiography -- left ventricular ejection fraction -- ultrasound enhancing agents
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.15318 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21095.xml