Clinical validation of an automatic atlas‐based segmentation tool for male pelvis CT images. Issue 3 (22nd January 2022)
- Record Type:
- Journal Article
- Title:
- Clinical validation of an automatic atlas‐based segmentation tool for male pelvis CT images. Issue 3 (22nd January 2022)
- Main Title:
- Clinical validation of an automatic atlas‐based segmentation tool for male pelvis CT images
- Authors:
- Casati, Marta
Piffer, Stefano
Calusi, Silvia
Marrazzo, Livia
Simontacchi, Gabriele
Di Cataldo, Vanessa
Greto, Daniela
Desideri, Isacco
Vernaleone, Marco
Francolini, Giulio
Livi, Lorenzo
Pallotta, Stefania - Abstract:
- Abstract: Purpose: This retrospective work aims to evaluate the possible impact on intra‐ and inter‐observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto‐segmentation tool in radiotherapy planning workflow. Methods: Tests were carried out on five structures (bladder, rectum, pelvic lymph‐nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re‐contour and edit auto‐contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto‐contours, producing automatic‐modified (AM) contours. The procedure was repeated to evaluate intra‐observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra‐ and inter‐observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as "clinically acceptable" or "to be corrected" in a blind test. Results: Comparing AM to M sets, a significant reduction of both inter‐observer variability ( p < 0.001) and contouring time (‐45% whole pelvis, p < 0.001) wasAbstract: Purpose: This retrospective work aims to evaluate the possible impact on intra‐ and inter‐observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto‐segmentation tool in radiotherapy planning workflow. Methods: Tests were carried out on five structures (bladder, rectum, pelvic lymph‐nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re‐contour and edit auto‐contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto‐contours, producing automatic‐modified (AM) contours. The procedure was repeated to evaluate intra‐observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra‐ and inter‐observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as "clinically acceptable" or "to be corrected" in a blind test. Results: Comparing AM to M sets, a significant reduction of both inter‐observer variability ( p < 0.001) and contouring time (‐45% whole pelvis, p < 0.001) was obtained. Intra‐observer variability reduction was significant only for bladder and femoral heads ( p < 0.001). The statistical test showed no significant bias. Conclusion: Our atlas‐based workflow proved to be effective for clinical practice as it can improve contour reproducibility and generate time savings. Based on these findings, institutions are encouraged to implement their auto‐segmentation method. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 3(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 3(2022)
- Issue Display:
- Volume 23, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2022-0023-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-01-22
- Subjects:
- auto‐contouring -- CT -- inter‐observer -- intra‐observer -- pelvis -- time savings
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13507 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21073.xml