Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion. Issue 4 (16th March 2022)
- Record Type:
- Journal Article
- Title:
- Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion. Issue 4 (16th March 2022)
- Main Title:
- Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion
- Authors:
- Zhang, Mingzheng
Ren, Weiyan
Mo, Zhongjun
Li, Jian
Pu, Fang
Fan, Yubo - Abstract:
- Abstract: Multi-level spinal fusion has been reported in some cases to lead to adjacent segment disease (ASD) and proximal junctional kyphosis (PJK). The purpose of this study was to demonstrate a polyether-ether-ketone (PEEK) rod fixation system implanted adjacent to a two-level lumbar fusion would have a lower risk of PJK than three-level lumbar fusion, which was investigated by comparing the biomechanical effects on the adjacent level after surgical procedures. Four finite element (FE) models of the lumbar-sacral spine (intact model (INT), L4-S1 fusion model (L4-S1 FUS), L3-S1 fusion model (L3-S1 FUS), and single-level PEEK rod semi-rigid fixation adjacent to L4-S1 fusion model (FUSPRF)) were established. Displacement-controlled finite element (FE) analysis was used during the simulation. Compared with the two-level fusion model (L4-S1 FUS), both three-level implanted models (L3-S1 FUS and FUSPRF) showed an increase intersegmental rotation angle, and maximum von-Mises stress on the disc annulus. The results also showed that the intersegmental rotation, stress on the disc annulus and maximum stress on the rod were lower in the FUSPRF model than the L3-S1 FUS model. Though the maximum screw stress was higher in the FUSPRF model than the L3-S1 FUS model under all moments except for torsion, the maximum screw stress in the two models were far below the yield strength of titanium alloy. As the parameters above have been indicated as risk factors for PJK, it can be concludedAbstract: Multi-level spinal fusion has been reported in some cases to lead to adjacent segment disease (ASD) and proximal junctional kyphosis (PJK). The purpose of this study was to demonstrate a polyether-ether-ketone (PEEK) rod fixation system implanted adjacent to a two-level lumbar fusion would have a lower risk of PJK than three-level lumbar fusion, which was investigated by comparing the biomechanical effects on the adjacent level after surgical procedures. Four finite element (FE) models of the lumbar-sacral spine (intact model (INT), L4-S1 fusion model (L4-S1 FUS), L3-S1 fusion model (L3-S1 FUS), and single-level PEEK rod semi-rigid fixation adjacent to L4-S1 fusion model (FUSPRF)) were established. Displacement-controlled finite element (FE) analysis was used during the simulation. Compared with the two-level fusion model (L4-S1 FUS), both three-level implanted models (L3-S1 FUS and FUSPRF) showed an increase intersegmental rotation angle, and maximum von-Mises stress on the disc annulus. The results also showed that the intersegmental rotation, stress on the disc annulus and maximum stress on the rod were lower in the FUSPRF model than the L3-S1 FUS model. Though the maximum screw stress was higher in the FUSPRF model than the L3-S1 FUS model under all moments except for torsion, the maximum screw stress in the two models were far below the yield strength of titanium alloy. As the parameters above have been indicated as risk factors for PJK, it can be concluded that hybrid single-level PEEK rod semi-rigid fixation and two-level lumbar fusion have a lower risk of PJK than three-level lumbar fusion. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 25:Issue 4(2022)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 25:Issue 4(2022)
- Issue Display:
- Volume 25, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2022-0025-0004-0000
- Page Start:
- 455
- Page End:
- 463
- Publication Date:
- 2022-03-16
- Subjects:
- Finite element analysis (FEA) -- PEEK rod -- proximal junctional kyphosis (PJK) -- adjacent segment disease (ASD) -- spinal fusion
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2021.1959557 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21040.xml