Cost-Effectiveness of Antibiotic-Eluting Envelope for Prevention of Cardiac Implantable Electronic Device Infections in Heart Failure. Issue 3 (2nd February 2022)
- Record Type:
- Journal Article
- Title:
- Cost-Effectiveness of Antibiotic-Eluting Envelope for Prevention of Cardiac Implantable Electronic Device Infections in Heart Failure. Issue 3 (2nd February 2022)
- Main Title:
- Cost-Effectiveness of Antibiotic-Eluting Envelope for Prevention of Cardiac Implantable Electronic Device Infections in Heart Failure
- Authors:
- Modi, Ronuk M.
Liu, Chia-Liang
Isaza, Nicolas
Raber, Inbar
Calvachi, Paola
Zimetbaum, Peter
Bellows, Brandon K.
Kramer, Daniel B.
Kazi, Dhruv S. - Abstract:
- Abstract : Supplemental Digital Content is available in the text. Abstract : Background: Use of an antibiotic-eluting envelope (AEE) during cardiac implantable electronic device procedures reduces infection risk but increases procedural costs. We aim to estimate the cost-effectiveness of AEE use during cardiac implantable electronic device procedures among patients with heart failure. Methods: A state-transition cohort model of heart failure patients undergoing cardiac implantable electronic device implantation or generator replacement was developed with input parameters estimated from randomized trials, registries, surveys, and claims data. Effectiveness was estimated from the World-Wide Randomized Antibiotic Envelope Infection Prevention Trial. AEE was assumed to cost $953 per unit. The model projected mortality, quality-adjusted life-years, costs, and the incremental cost-effectiveness ratio of AEE use compared with usual care from a US healthcare sector perspective over a lifetime horizon. We assumed a cost-effectiveness threshold of $100 000 per quality-adjusted life-year gained. Results: Compared with usual care, AEE use in initial implantations produced an incremental cost-effectiveness ratio of $112 000 per quality-adjusted life-year gained (39% probability of being cost-effective). In generator replacement procedures, AEE use produced an incremental cost-effectiveness ratio of $54 000 per quality-adjusted life-year gained (84% probability of being cost-effective).Abstract : Supplemental Digital Content is available in the text. Abstract : Background: Use of an antibiotic-eluting envelope (AEE) during cardiac implantable electronic device procedures reduces infection risk but increases procedural costs. We aim to estimate the cost-effectiveness of AEE use during cardiac implantable electronic device procedures among patients with heart failure. Methods: A state-transition cohort model of heart failure patients undergoing cardiac implantable electronic device implantation or generator replacement was developed with input parameters estimated from randomized trials, registries, surveys, and claims data. Effectiveness was estimated from the World-Wide Randomized Antibiotic Envelope Infection Prevention Trial. AEE was assumed to cost $953 per unit. The model projected mortality, quality-adjusted life-years, costs, and the incremental cost-effectiveness ratio of AEE use compared with usual care from a US healthcare sector perspective over a lifetime horizon. We assumed a cost-effectiveness threshold of $100 000 per quality-adjusted life-year gained. Results: Compared with usual care, AEE use in initial implantations produced an incremental cost-effectiveness ratio of $112 000 per quality-adjusted life-year gained (39% probability of being cost-effective). In generator replacement procedures, AEE use produced an incremental cost-effectiveness ratio of $54 000 per quality-adjusted life-year gained (84% probability of being cost-effective). Results were sensitive to the underlying rate of infection, cost of the AEE, and durability of AEE effectiveness. Conclusions: Universal AEE use for cardiac implantable electronic device procedures in patients with heart failure with reduced ejection fraction is unlikely to be cost-effective, reinforcing the need for individualized risk assessment to guide uptake of the AEE in clinical practice. Selective use in patients at increased risk of infection, such as those undergoing generator replacement procedures, is more likely to meet health system value benchmarks. … (more)
- Is Part Of:
- Circulation. Volume 15:Issue 3(2022)
- Journal:
- Circulation
- Issue:
- Volume 15:Issue 3(2022)
- Issue Display:
- Volume 15, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 15
- Issue:
- 3
- Issue Sort Value:
- 2022-0015-0003-0000
- Page Start:
- e008443
- Page End:
- Publication Date:
- 2022-02-02
- Subjects:
- cardiac resynchronization therapy -- heart failure -- implantable defibrillator -- infection -- morbidity
Cardiovascular system -- Diseases -- Treatment -- Periodicals
Cardiovascular system -- Diseases -- Research -- Periodicals
Outcome assessment (Medical care) -- Periodicals
Evidence-based medicine -- Periodicals
616.1007 - Journal URLs:
- http://circoutcomes.ahajournals.org ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337496-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCOUTCOMES.121.008443 ↗
- Languages:
- English
- ISSNs:
- 1941-7713
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.263000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21057.xml