Direct and indirect effects of membrane pore size on fouling development in a submerged membrane bioreactor with a symmetric chlorinated poly (vinyl chloride) flat-sheet membrane. Issue 2 (April 2022)
- Record Type:
- Journal Article
- Title:
- Direct and indirect effects of membrane pore size on fouling development in a submerged membrane bioreactor with a symmetric chlorinated poly (vinyl chloride) flat-sheet membrane. Issue 2 (April 2022)
- Main Title:
- Direct and indirect effects of membrane pore size on fouling development in a submerged membrane bioreactor with a symmetric chlorinated poly (vinyl chloride) flat-sheet membrane
- Authors:
- Sano, Toshio
Kawagoshi, Yasunori
Kokubo, Ituki
Ito, Hiroaki
Ishida, Kei
Sato, Akira - Abstract:
- Abstract: Membrane bioreactors (MBRs) have been recognized as a promising wastewater treatment technique because of their superior solid–liquid separation performance; however, fouling development remains a concern. In this study, the relationship between membrane pore size and fouling development is investigated using originally prepared chlorinated polyvinyl chloride (CPVC) flat-sheet membranes with different pore sizes in MBRs; further, the mechanism of fouling development is demonstrated. Under the conditions in this study, the optimal membrane pore size for suppressing fouling development was determined to be in the range of 0.31–0.57 µm. It was also demonstrated that irreversible fouling is closely related to the capture of protein-like compounds inside the membrane; in contrast, it was considered that reversible fouling is caused by gel and cake layers formed on the membrane surface. Moreover, it was indicated that the membrane pore size directly and indirectly affected both reversible and irreversible fouling through the mutual relationship with other membrane characteristics such as the surface roughness. Finally, it is concluded that the optimal membrane pore size for suppressing fouling development is determined by the total filtration resistance caused by irreversible and reversible fouling phenomena. Graphical Abstract: ga1 Highlights: Optimal pore size of CPVC membrane for suppressing fouling is around 0.31–0.57 µm. Total resistance of irreversible & reversibleAbstract: Membrane bioreactors (MBRs) have been recognized as a promising wastewater treatment technique because of their superior solid–liquid separation performance; however, fouling development remains a concern. In this study, the relationship between membrane pore size and fouling development is investigated using originally prepared chlorinated polyvinyl chloride (CPVC) flat-sheet membranes with different pore sizes in MBRs; further, the mechanism of fouling development is demonstrated. Under the conditions in this study, the optimal membrane pore size for suppressing fouling development was determined to be in the range of 0.31–0.57 µm. It was also demonstrated that irreversible fouling is closely related to the capture of protein-like compounds inside the membrane; in contrast, it was considered that reversible fouling is caused by gel and cake layers formed on the membrane surface. Moreover, it was indicated that the membrane pore size directly and indirectly affected both reversible and irreversible fouling through the mutual relationship with other membrane characteristics such as the surface roughness. Finally, it is concluded that the optimal membrane pore size for suppressing fouling development is determined by the total filtration resistance caused by irreversible and reversible fouling phenomena. Graphical Abstract: ga1 Highlights: Optimal pore size of CPVC membrane for suppressing fouling is around 0.31–0.57 µm. Total resistance of irreversible & reversible fouling determines optimal pore size. Pore size has multiple effects on fouling with other membrane characteristics. Capture of protein-like compound in membrane might be tied to irreversible fouling. … (more)
- Is Part Of:
- Journal of environmental chemical engineering. Volume 10:Issue 2(2022)
- Journal:
- Journal of environmental chemical engineering
- Issue:
- Volume 10:Issue 2(2022)
- Issue Display:
- Volume 10, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2022-0010-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-04
- Subjects:
- Membrane bioreactor -- Membrane fouling -- Chlorinated polyvinyl chloride -- Membrane pore size -- Filtration resistance
Chemical engineering -- Environmental aspects -- Periodicals
Environmental engineering -- Periodicals
Chemical engineering -- Environmental aspects
Environmental engineering
Periodicals
660.0286 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22133437 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jece.2021.107023 ↗
- Languages:
- English
- ISSNs:
- 2213-2929
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20998.xml