Evaluation of Tibial Fixation Devices for Quadrupled Hamstring ACL Reconstruction. Issue 5 (11th May 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of Tibial Fixation Devices for Quadrupled Hamstring ACL Reconstruction. Issue 5 (11th May 2022)
- Main Title:
- Evaluation of Tibial Fixation Devices for Quadrupled Hamstring ACL Reconstruction
- Authors:
- Ammann, Elias
Hecker, Andreas
Bachmann, Elias
Snedeker, Jess G.
Fucentese, Sandro F. - Abstract:
- Background: Shortcomings to tibial-side fixation have been reported as causes of failure after anterior cruciate ligament reconstruction. Adjustable-loop suspensory devices have become popular; however, no comparison with hybrid fixation (ie, interference screw and cortical button) exists to our knowledge. Purpose: The purpose of this study was to compare the biomechanical properties of adjustable loop devices (ALDs) in full-tunnel and closed-socket configurations in relation to hybrid fixation. We hypothesized that primary stability of fixation by a tibial ALD will not be inferior to hybrid fixation. Study Design: Controlled laboratory study. Methods: Tibial fixation of a quadrupled tendon graft was biomechanically investigated in a porcine tibia–bovine tendon model using 5 techniques (n = 6 specimens each). The tested constructs included hybrid fixation with a cortical fixation button and interference screw (group 1), single cortical fixation with the full-tunnel technique using an open-suture strand button (group 2) or an ALD (group 3), or closed-socket fixation using 2 different types of ALDs (groups 4 and 5). Each specimen was evaluated using a materials testing machine (1000 cycles from 50-250 N and pull to failure). Force at failure, cyclic displacement, stiffness, and ability to pretension the graft during insertion were compared among the groups. Results: No differences in ultimate load to failure were found between the ALD constructs (groups 3, 4, and 5) and hybridBackground: Shortcomings to tibial-side fixation have been reported as causes of failure after anterior cruciate ligament reconstruction. Adjustable-loop suspensory devices have become popular; however, no comparison with hybrid fixation (ie, interference screw and cortical button) exists to our knowledge. Purpose: The purpose of this study was to compare the biomechanical properties of adjustable loop devices (ALDs) in full-tunnel and closed-socket configurations in relation to hybrid fixation. We hypothesized that primary stability of fixation by a tibial ALD will not be inferior to hybrid fixation. Study Design: Controlled laboratory study. Methods: Tibial fixation of a quadrupled tendon graft was biomechanically investigated in a porcine tibia–bovine tendon model using 5 techniques (n = 6 specimens each). The tested constructs included hybrid fixation with a cortical fixation button and interference screw (group 1), single cortical fixation with the full-tunnel technique using an open-suture strand button (group 2) or an ALD (group 3), or closed-socket fixation using 2 different types of ALDs (groups 4 and 5). Each specimen was evaluated using a materials testing machine (1000 cycles from 50-250 N and pull to failure). Force at failure, cyclic displacement, stiffness, and ability to pretension the graft during insertion were compared among the groups. Results: No differences in ultimate load to failure were found between the ALD constructs (groups 3, 4, and 5) and hybrid fixation (group 1). Cyclic displacement was significantly higher in group 2 vs all other groups ( P < .001); however, no difference was observed in groups 3, 4, and 5 as compared with group 1. The remaining tension on the construct after fixation was significantly higher in groups 3 and 4 vs groups 1, 2, and 5 ( P < .02 for all comparisons), irrespective of whether a full-tunnel or closed-socket approach was used. Conclusion: Tibial anterior cruciate ligament graft fixation with knotless ALDs achieved comparable results with hybrid fixation in the full-tunnel and closed-socket techniques. The retention of graft tension appears to be biomechanically more relevant than tunnel type. Clinical Relevance: The study findings emphasize the importance of the tension at which fixation is performed. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 10:Issue 5(2022)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 10:Issue 5(2022)
- Issue Display:
- Volume 10, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 5
- Issue Sort Value:
- 2022-0010-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-11
- Subjects:
- anterior cruciate ligament -- tibia -- fixation -- biomechanics
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/23259671221096107 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20977.xml