First clinical evaluation of breathing controlled four-dimensional computed tomography imaging. (October 2021)
- Record Type:
- Journal Article
- Title:
- First clinical evaluation of breathing controlled four-dimensional computed tomography imaging. (October 2021)
- Main Title:
- First clinical evaluation of breathing controlled four-dimensional computed tomography imaging
- Authors:
- Szkitsak, Juliane
Werner, René
Fernolendt, Susanne
Schwarz, Annette
Ott, Oliver J.
Fietkau, Rainer
Hofmann, Christian
Bert, Christoph - Abstract:
- Abstract: Background and Purpose: Four-dimensional computed tomography (4DCT) has become an essential part of radiotherapy planning but is often affected by artifacts. A new breathing controlled 4DCT (i4DCT) algorithm has been introduced. This study aims to present the first clinical data and to evaluate the achieved image quality, projection data coverage and beam-on time. Material & Methods: The analysis included i4DCT data for 129 scans of patients with thoracic tumors. Projection data coverage and beam-on time were evaluated. Additionally, image quality was exemplarily discussed and rated by ten clinical experts with a 5-score-scale for 30 patients with large variations in their breathing pattern ('challenging subgroup'). Rated images were reconstructed amplitude- and phase-based. Results: Expert scoring revealed that 78% (amplitude-based) and 63% (phase-based) of the challenging subgroup were artifact-free (rating ≥4). For the entire cohort, average beam-on time per couch position was 4.9 ± 1.6 s. For the challenging subgroup, time increased slightly but not significantly compared to the remaining patients (5.1 s vs. 4.9 s; p = 0.64). Median projection data coverage was 93% and 94% for inhalation and exhalation, respectively, for the entire cohort. The comparison for the subgroup and the remaining patients revealed a small but significant decrease of the median coverage values for the challenging cases (inhalation: 90% vs. 94%, p = 0.02; exhalation: 93% vs. 94%,Abstract: Background and Purpose: Four-dimensional computed tomography (4DCT) has become an essential part of radiotherapy planning but is often affected by artifacts. A new breathing controlled 4DCT (i4DCT) algorithm has been introduced. This study aims to present the first clinical data and to evaluate the achieved image quality, projection data coverage and beam-on time. Material & Methods: The analysis included i4DCT data for 129 scans of patients with thoracic tumors. Projection data coverage and beam-on time were evaluated. Additionally, image quality was exemplarily discussed and rated by ten clinical experts with a 5-score-scale for 30 patients with large variations in their breathing pattern ('challenging subgroup'). Rated images were reconstructed amplitude- and phase-based. Results: Expert scoring revealed that 78% (amplitude-based) and 63% (phase-based) of the challenging subgroup were artifact-free (rating ≥4). For the entire cohort, average beam-on time per couch position was 4.9 ± 1.6 s. For the challenging subgroup, time increased slightly but not significantly compared to the remaining patients (5.1 s vs. 4.9 s; p = 0.64). Median projection data coverage was 93% and 94% for inhalation and exhalation, respectively, for the entire cohort. The comparison for the subgroup and the remaining patients revealed a small but significant decrease of the median coverage values for the challenging cases (inhalation: 90% vs. 94%, p = 0.02; exhalation: 93% vs. 94%, p = 0.02). Conclusions: This first clinical evaluation of i4DCT shows very promising results in terms of image quality and projection data coverage. The results agree with and support the results of previous i4DCT phantom studies. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 20(2021)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 20(2021)
- Issue Display:
- Volume 20, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 20
- Issue:
- 2021
- Issue Sort Value:
- 2021-0020-2021-0000
- Page Start:
- 56
- Page End:
- 61
- Publication Date:
- 2021-10
- Subjects:
- 4DCT -- Motion artifacts -- Respiratory motion
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2021.09.005 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20959.xml