High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition. (February 2018)
- Record Type:
- Journal Article
- Title:
- High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition. (February 2018)
- Main Title:
- High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition
- Authors:
- Schässburger, Kai-Uwe
Paepke, Stefan
Saracco, Ariel
Azavedo, Edward
Ekström, Christina
Wiksell, Hans - Abstract:
- Highlights: New biopsy system for breast and axillary lymph nodes. Pneumatic mechanism intended for better control and precise lesion targeting. Achieves higher needle acceleration, velocity and power compared to current devices. Collects significantly more tissue than standard biopsy device in bench models. Abstract: Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsyHighlights: New biopsy system for breast and axillary lymph nodes. Pneumatic mechanism intended for better control and precise lesion targeting. Achieves higher needle acceleration, velocity and power compared to current devices. Collects significantly more tissue than standard biopsy device in bench models. Abstract: Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsy devices. Mean weight of samples obtained by the NeoNavia device were 3.5, 4.6, and 4.3 times higher when sampling was performed in turkey breast, calf thymus and swine pancreas, respectively, as compared to samples obtained with the Magnum instrument. Ex-vivo analysis indicates that the method of tissue acquisition has no apparent negative impact on the histopathologic quality of obtained samples. … (more)
- Is Part Of:
- Physica medica. Volume 46(2018)
- Journal:
- Physica medica
- Issue:
- Volume 46(2018)
- Issue Display:
- Volume 46, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 2018
- Issue Sort Value:
- 2018-0046-2018-0000
- Page Start:
- 25
- Page End:
- 31
- Publication Date:
- 2018-02
- Subjects:
- Breast -- Axilla -- Biopsy -- CNB -- VAB -- Needle -- Ultrasound
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.12.014 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20949.xml