Improvement of VMAT plan quality for head and neck cancer with high resolution fluences generated by couch shift between arcs. (February 2018)
- Record Type:
- Journal Article
- Title:
- Improvement of VMAT plan quality for head and neck cancer with high resolution fluences generated by couch shift between arcs. (February 2018)
- Main Title:
- Improvement of VMAT plan quality for head and neck cancer with high resolution fluences generated by couch shift between arcs
- Authors:
- Park, Jong Min
Park, So-Yeon
Wu, Hong-Gyun
Kim, Jung-in - Abstract:
- Highlights: Use half of MLC leaf width by shifting patient couch. Increasing fluence resolution by shifting patient couch. Improved VMAT plan quality for nasopharyngeal cancer. Reduced MU for VMAT plan with shifting patient couch. Abstract: Purpose: To investigate the changes in quality of the volumetric modulated arc therapy (VMAT) plans with couch-shift between arcs by half of a multi-leaf collimator (MLC) leaf width. Methods: A total of 22 patients with head-and-neck cancer were retrospectively selected. Since the smallest MLC leaf width was 5 mm in this study, the couch was shifted by 2.5 mm in the longitudinal-direction between arcs to increase the resolution of fluence map. A total of three types of VMAT plans were generated for each patient; the three types of plans were a two-full-arc plan without couch-shift ( NS plan ), a two-half-arc-pair plan with couch-shift ( HAS plan ), and a two-full-arc pair plan with couch-shift ( FAS plan ). Changes in the dose-volumetric parameters were investigated. Results: The FAS plan showed the best plan quality for the target volumes and organs at risk compared to the NS and HAS plans . However, the magnitudes of differences among the three types of plans were minimal, and every plan was clinically acceptable. The average integral doses of the NS, HAS, and FAS plans were 160, 549 ± 37, 600 Gy-cc, 147, 828 ± 33, 343 Gy-cc, and 156, 030 ± 36, 263 Gy-cc, respectively. The average monitor unit of the NS, HAS, and FAS plans wereHighlights: Use half of MLC leaf width by shifting patient couch. Increasing fluence resolution by shifting patient couch. Improved VMAT plan quality for nasopharyngeal cancer. Reduced MU for VMAT plan with shifting patient couch. Abstract: Purpose: To investigate the changes in quality of the volumetric modulated arc therapy (VMAT) plans with couch-shift between arcs by half of a multi-leaf collimator (MLC) leaf width. Methods: A total of 22 patients with head-and-neck cancer were retrospectively selected. Since the smallest MLC leaf width was 5 mm in this study, the couch was shifted by 2.5 mm in the longitudinal-direction between arcs to increase the resolution of fluence map. A total of three types of VMAT plans were generated for each patient; the three types of plans were a two-full-arc plan without couch-shift ( NS plan ), a two-half-arc-pair plan with couch-shift ( HAS plan ), and a two-full-arc pair plan with couch-shift ( FAS plan ). Changes in the dose-volumetric parameters were investigated. Results: The FAS plan showed the best plan quality for the target volumes and organs at risk compared to the NS and HAS plans . However, the magnitudes of differences among the three types of plans were minimal, and every plan was clinically acceptable. The average integral doses of the NS, HAS, and FAS plans were 160, 549 ± 37, 600 Gy-cc, 147, 828 ± 33, 343 Gy-cc, and 156, 030 ± 36, 263 Gy-cc, respectively. The average monitor unit of the NS, HAS, and FAS plans were 717 ± 120 MU, 648 ± 100 MU, and 763 ± 158 MU, respectively. Conclusions: The HAS plan was better than the others in terms of normal tissue sparing and plan efficiency. By shifting the couch by half of the MLC leaf width in the longitudinal direction between arcs, the VMAT plan quality could be improved. … (more)
- Is Part Of:
- Physica medica. Volume 46(2018)
- Journal:
- Physica medica
- Issue:
- Volume 46(2018)
- Issue Display:
- Volume 46, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 2018
- Issue Sort Value:
- 2018-0046-2018-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2018-02
- Subjects:
- Fluence -- Planning study -- Head and neck -- Leaf width
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.01.004 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20949.xml