Cone-beam CT-based inter-fraction localization errors for tumors in the pelvic region. (February 2018)
- Record Type:
- Journal Article
- Title:
- Cone-beam CT-based inter-fraction localization errors for tumors in the pelvic region. (February 2018)
- Main Title:
- Cone-beam CT-based inter-fraction localization errors for tumors in the pelvic region
- Authors:
- Garibaldi, Cristina
Fodor, Cristiana
Riva, Giulia
Rojas, Damaris Patricia
Dicuonzo, Samantha
Pace, Elisa
Fanetti, Giuseppe
De Marco, Paolo
Dell'acqua, Veronica
Marvaso, Giulia
Leonardi, Maria Cristina
Lazzari, Roberta
Cattani, Federica
Cremonesi, Marta
Orecchia, Roberto
Jereczek-Fossa, Barbara Alicja - Abstract:
- Highlights: Inter-fraction localization errors for 928 patients with pelvic tumors were evaluated with CBCT. Online daily and weekly IGRT protocols were used. Appropriate CTV-to-PTV margins in non IGRT scenario have been proposed. Without IGRT, large CTV-to-PTV margins up to 15 mm are required to account for inter-fraction tumor localization errors. Abstract: Purpose: To evaluate inter-fraction tumor localization errors (TE) in the RapidArc® treatment of pelvic cancers based on CBCT. Appropriate CTV-to PTV margins in a non-IGRT scenario have been proposed. Methods: Data of 928 patients with prostate, gynecological, and rectum/anal canal cancers were retrospectively analyzed to determine systematic and random localization errors. Two protocols were used: daily online IGRT (d-IGRT) and weekly IGRT. The latter consisted in acquiring a CBCT for the first 3 fractions and subsequently once a week. TE for patients who underwent d-IGRT protocol were calculated using either all CBCTs or the first 3. Results: The systematic (and random) TE in the AP, LL, and SI direction were: for prostate bed 2.7(3.2), 2.3(2.8) and 1.9(2.2) mm; for prostate 4.2(3.1), 2.9(2.8) and 2.3(2.2) mm; for gynecological 3.0(3.6), 2.4(2.7) and 2.3(2.5) mm; for rectum 2.8(2.8), 2.4(2.8) and 2.3(2.5) mm; for anal canal 3.1(3.3), 2.1(2.5) and 2.2(2.7) mm. CTV-to-PTV margins determined from all CBCTs were 14 mm in the AP, 10 mm in the LL and 9–9.5 mm in the SI directions for the prostate and the gynecologicalHighlights: Inter-fraction localization errors for 928 patients with pelvic tumors were evaluated with CBCT. Online daily and weekly IGRT protocols were used. Appropriate CTV-to-PTV margins in non IGRT scenario have been proposed. Without IGRT, large CTV-to-PTV margins up to 15 mm are required to account for inter-fraction tumor localization errors. Abstract: Purpose: To evaluate inter-fraction tumor localization errors (TE) in the RapidArc® treatment of pelvic cancers based on CBCT. Appropriate CTV-to PTV margins in a non-IGRT scenario have been proposed. Methods: Data of 928 patients with prostate, gynecological, and rectum/anal canal cancers were retrospectively analyzed to determine systematic and random localization errors. Two protocols were used: daily online IGRT (d-IGRT) and weekly IGRT. The latter consisted in acquiring a CBCT for the first 3 fractions and subsequently once a week. TE for patients who underwent d-IGRT protocol were calculated using either all CBCTs or the first 3. Results: The systematic (and random) TE in the AP, LL, and SI direction were: for prostate bed 2.7(3.2), 2.3(2.8) and 1.9(2.2) mm; for prostate 4.2(3.1), 2.9(2.8) and 2.3(2.2) mm; for gynecological 3.0(3.6), 2.4(2.7) and 2.3(2.5) mm; for rectum 2.8(2.8), 2.4(2.8) and 2.3(2.5) mm; for anal canal 3.1(3.3), 2.1(2.5) and 2.2(2.7) mm. CTV-to-PTV margins determined from all CBCTs were 14 mm in the AP, 10 mm in the LL and 9–9.5 mm in the SI directions for the prostate and the gynecological groups and 9.5–10.5 mm in AP, 9 mm in LL and 8–10 mm in the SI direction for the prostate bed and the rectum/anal canal groups. If assessed on the basis of the first 3 CBCTs, the calculated CTV-to-PTV margins were slightly larger. Conclusions: without IGRT, large CTV-to-PTV margins up to 15 mm are required to account for inter-fraction tumor localization errors. Daily IGRT should be used for all hypo-fractionated treatments to reduce margins and avoid increased toxicity to critical organs. … (more)
- Is Part Of:
- Physica medica. Volume 46(2018)
- Journal:
- Physica medica
- Issue:
- Volume 46(2018)
- Issue Display:
- Volume 46, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 2018
- Issue Sort Value:
- 2018-0046-2018-0000
- Page Start:
- 59
- Page End:
- 66
- Publication Date:
- 2018-02
- Subjects:
- Image-guided radiotherapy -- Cone-beam computed tomography -- Tumor localization errors -- Prostate cancer -- Gynecological cancer -- Rectum cancer
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.01.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20949.xml