Long‐T2‐suppressed zero echo time imaging with weighted echo subtraction and gradient error correction. Issue 2 (10th September 2019)
- Record Type:
- Journal Article
- Title:
- Long‐T2‐suppressed zero echo time imaging with weighted echo subtraction and gradient error correction. Issue 2 (10th September 2019)
- Main Title:
- Long‐T2‐suppressed zero echo time imaging with weighted echo subtraction and gradient error correction
- Authors:
- Lee, Hyo Min
Weiger, Markus
Giehr, Caspar
Froidevaux, Romain
Brunner, David Otto
Rösler, Manuela Barbara
Pruessmann, Klaas Paul - Abstract:
- Abstract : Purpose: To perform direct, selective MRI of short‐T2 tissues using zero echo time (ZTE) imaging with weighted echo subtraction (WSUB). Methods: Radial imaging was performed at 7T, acquiring both ZTE and gradient echo (GRE) signals created by bipolar gradients. Long‐T2 suppression was achieved by weighted subtraction of ZTE and GRE images. Special attention was given to imperfections of gradient dynamics, to which radial GRE imaging is particularly susceptible. To compensate for gradient errors, matching of gradient history was combined with data correction based on trajectory measurement. The proposed approach was first validated in phantom experiments and then demonstrated in musculoskeletal (MSK) imaging. Results: Trajectory analysis and phantom imaging demonstrated that gradient imperfections were successfully addressed. Gradient history matching enabled consistency between antiparallel projections as required for deriving zeroth‐order eddy current dynamics. Trajectory measurement provided individual echo times per projection that showed considerable variation between gradient directions. In in vivo imaging of knee, ankle, and tibia, the proposed approach enabled high‐resolution 3D depiction of bone, tendons, and ligaments. Distinct contrast of these structures indicates excellent selectivity of long‐T2 suppression. Clarity of depiction also confirmed sufficient SNR of short‐T2 tissues, achieved by high baseline sensitivity at 7T combined with high SNRAbstract : Purpose: To perform direct, selective MRI of short‐T2 tissues using zero echo time (ZTE) imaging with weighted echo subtraction (WSUB). Methods: Radial imaging was performed at 7T, acquiring both ZTE and gradient echo (GRE) signals created by bipolar gradients. Long‐T2 suppression was achieved by weighted subtraction of ZTE and GRE images. Special attention was given to imperfections of gradient dynamics, to which radial GRE imaging is particularly susceptible. To compensate for gradient errors, matching of gradient history was combined with data correction based on trajectory measurement. The proposed approach was first validated in phantom experiments and then demonstrated in musculoskeletal (MSK) imaging. Results: Trajectory analysis and phantom imaging demonstrated that gradient imperfections were successfully addressed. Gradient history matching enabled consistency between antiparallel projections as required for deriving zeroth‐order eddy current dynamics. Trajectory measurement provided individual echo times per projection that showed considerable variation between gradient directions. In in vivo imaging of knee, ankle, and tibia, the proposed approach enabled high‐resolution 3D depiction of bone, tendons, and ligaments. Distinct contrast of these structures indicates excellent selectivity of long‐T2 suppression. Clarity of depiction also confirmed sufficient SNR of short‐T2 tissues, achieved by high baseline sensitivity at 7T combined with high SNR efficiency of ZTE acquisition. Conclusion: Weighted subtraction of ZTE and GRE data reconciles robust long‐T2 suppression with fastest k‐space coverage and high SNR efficiency. This approach enables high‐resolution imaging with excellent selectivity to short‐T2 tissues, which are of major interest in MSK and neuroimaging applications. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 2(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 2(2020)
- Issue Display:
- Volume 83, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 2
- Issue Sort Value:
- 2020-0083-0002-0000
- Page Start:
- 412
- Page End:
- 426
- Publication Date:
- 2019-09-10
- Subjects:
- bone -- eddy currents -- ligaments -- musculoskeletal imaging -- short‐T2 imaging -- tendons
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27925 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20933.xml