Real Time Monitoring During Cochlear Implantation: Increasing the Accuracy of Predicting Residual Hearing Outcomes. Issue 8 (14th September 2021)
- Record Type:
- Journal Article
- Title:
- Real Time Monitoring During Cochlear Implantation: Increasing the Accuracy of Predicting Residual Hearing Outcomes. Issue 8 (14th September 2021)
- Main Title:
- Real Time Monitoring During Cochlear Implantation: Increasing the Accuracy of Predicting Residual Hearing Outcomes
- Authors:
- Weder, Stefan
Bester, Christofer
Collins, Aaron
Shaul, Chanan
Briggs, Robert J.
O'Leary, Stephen - Abstract:
- Abstract : Objectives: Real-time electrocochleography (rt-ECochG) is a method to detect intracochlear potential changes during cochlear implantation (CI). Steep amplitude drops of the cochlear microphonic (CM) signal (so called "ECochG events") have been correlated with worse residual hearing outcomes. However, the sensitivity and specificity of monitoring CM amplitude on its own are too low to use it as a biomarker. The aim of this article was to establish if additional signal components would help to better predict postoperative hearing outcomes. Design and Setting: Single-center, prospective cohort study at a tertiary referral hospital. Participants and Interventions: Between 2017 and 2020, we included 73 adult patients receiving a lateral wall cochlear implant electrode. During electrode insertion, rt-ECochG measurements were performed. Main Outcomes: We calculated a multiple regression analysis for patients with one ECochG event. The dependant variable was the relative acoustic hearing result 4 weeks after surgery. Independent variables were CM latency, a ratio of the auditory nerve neurophonic to the CM (the ANN/CM index) as well as CM signal recovery. Results: The change of the ANN/CM index linearly correlated with acoustic hearing outcomes 4 weeks after surgery. Adding this factor led to a statistically significant increase in the variance accounted for by the regression model. Conclusions: When monitoring the implantation process with rt-ECochG, prediction ofAbstract : Objectives: Real-time electrocochleography (rt-ECochG) is a method to detect intracochlear potential changes during cochlear implantation (CI). Steep amplitude drops of the cochlear microphonic (CM) signal (so called "ECochG events") have been correlated with worse residual hearing outcomes. However, the sensitivity and specificity of monitoring CM amplitude on its own are too low to use it as a biomarker. The aim of this article was to establish if additional signal components would help to better predict postoperative hearing outcomes. Design and Setting: Single-center, prospective cohort study at a tertiary referral hospital. Participants and Interventions: Between 2017 and 2020, we included 73 adult patients receiving a lateral wall cochlear implant electrode. During electrode insertion, rt-ECochG measurements were performed. Main Outcomes: We calculated a multiple regression analysis for patients with one ECochG event. The dependant variable was the relative acoustic hearing result 4 weeks after surgery. Independent variables were CM latency, a ratio of the auditory nerve neurophonic to the CM (the ANN/CM index) as well as CM signal recovery. Results: The change of the ANN/CM index linearly correlated with acoustic hearing outcomes 4 weeks after surgery. Adding this factor led to a statistically significant increase in the variance accounted for by the regression model. Conclusions: When monitoring the implantation process with rt-ECochG, prediction of postoperative hearing thresholds is improved by addition of the ANN/CM index to a model that includes CM amplitude fluctuation. … (more)
- Is Part Of:
- Otology & neurotology. Volume 42:Issue 8(2021)
- Journal:
- Otology & neurotology
- Issue:
- Volume 42:Issue 8(2021)
- Issue Display:
- Volume 42, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 8
- Issue Sort Value:
- 2021-0042-0008-0000
- Page Start:
- e1030
- Page End:
- e1036
- Publication Date:
- 2021-09-14
- Subjects:
- ANN/CM index -- Auditory neurophonic -- Cochlear microphonic -- Latency change -- Real-time electrocochleography -- Residual hearing
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000003177 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20925.xml