Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening. Issue 11 (November 2020)
- Main Title:
- Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening
- Authors:
- Sepehri, Aresh
Martinson, James
Marchand, Lucas S.
Riedel, Matthew D.
McAlister, Ian P.
O'Hara, Nathan N.
Stockton, David J.
Slobogean, Gerard P. - Abstract:
- Abstract : Objectives: The purpose of this study is to compare the reliability and accuracy of the screw protuberance method (SPM) and overlay method (OM) for measuring femoral neck shortening on anterior–posterior (AP) radiographs. The secondary aim is to investigate the changes in reliability and accuracy with varying femoral rotation. Methods: Radio-opaque femur sawbone models were fitted with either 3 cancellous screws or a sliding hip screw implant. Anterior–posterior radiographs were obtained using C-arm fluoroscopy with femoral neck shortening up to 15 mm and with the femoral shaft in 30 degrees of internal rotation to 30 degrees of external rotation (ER). Four observers measured femoral neck shortening at 2 time points. Intraobserver and interobserver reliability were calculated using the intraclass coefficient. Accuracy was analyzed through a Bland–Altman agreement statistic stratified by femoral rotation. Results: Both measurement techniques displayed excellent reliability, regardless of femoral rotation or implant. There was a significant difference in femoral neck shortening measurements with rotation for both the OM ( P < 0.001) and SPM ( P < 0.001). Both methods are accurate within 1 mm of the actual magnitude of shortening from 30-degree internal rotation to 15-degree ER. At 30-degree ER, shortening was underestimated by −2.10 mm using the OM (95% confidence interval, −2.43 to −1.76; P < 0.01) and by −1.64 mm using the SPM (95% confidence interval, −1.83 toAbstract : Objectives: The purpose of this study is to compare the reliability and accuracy of the screw protuberance method (SPM) and overlay method (OM) for measuring femoral neck shortening on anterior–posterior (AP) radiographs. The secondary aim is to investigate the changes in reliability and accuracy with varying femoral rotation. Methods: Radio-opaque femur sawbone models were fitted with either 3 cancellous screws or a sliding hip screw implant. Anterior–posterior radiographs were obtained using C-arm fluoroscopy with femoral neck shortening up to 15 mm and with the femoral shaft in 30 degrees of internal rotation to 30 degrees of external rotation (ER). Four observers measured femoral neck shortening at 2 time points. Intraobserver and interobserver reliability were calculated using the intraclass coefficient. Accuracy was analyzed through a Bland–Altman agreement statistic stratified by femoral rotation. Results: Both measurement techniques displayed excellent reliability, regardless of femoral rotation or implant. There was a significant difference in femoral neck shortening measurements with rotation for both the OM ( P < 0.001) and SPM ( P < 0.001). Both methods are accurate within 1 mm of the actual magnitude of shortening from 30-degree internal rotation to 15-degree ER. At 30-degree ER, shortening was underestimated by −2.10 mm using the OM (95% confidence interval, −2.43 to −1.76; P < 0.01) and by −1.64 mm using the SPM (95% confidence interval, −1.83 to −1.45; P < 0.01). Conclusion: This study demonstrates that both the OM and SPM are accurate and reliable assessments for femoral neck shortening; however, both methods are sensitive to extreme ER. Given the simplicity of the SPM technique, it may have increased utility for pragmatic research studies. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 34:Issue 11(2020)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 34:Issue 11(2020)
- Issue Display:
- Volume 34, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2020-0034-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- femoral neck shortening -- psychometric analysis -- reliability -- validity -- accuracy
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001806 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20918.xml