Cardiac output measurements during high‐risk Cesarean section using electrical bioreactance or arterial waveform analysis: assessment of agreement. (11th July 2019)
- Record Type:
- Journal Article
- Title:
- Cardiac output measurements during high‐risk Cesarean section using electrical bioreactance or arterial waveform analysis: assessment of agreement. (11th July 2019)
- Main Title:
- Cardiac output measurements during high‐risk Cesarean section using electrical bioreactance or arterial waveform analysis: assessment of agreement
- Authors:
- Gutierrez, J.
Perry, H.
Columb, M.
Bampoe, S.
Thilaganathan, B.
Khalil, A. - Abstract:
- ABSTRACT: Objective: Maternal hemodynamics change significantly during Cesarean section complicated by massive hemorrhage or severe hypertensive disease. Cardiac output (CO) monitoring aids early, goal‐directed hemodynamic therapy. The aim of this study was to record hemodynamic changes observed during Cesarean section in pregnancies at high risk of hemodynamic instability, using invasive (LiDCOrapid™) and non‐invasive (NICOM®) devices, and to assess agreement between the two devices in measuring CO. Methods: Simultaneous intraoperative hemodynamic measurements were taken using the LiDCOrapid and NICOM devices, following standardized techniques, in women at high risk of hemodynamic instability undergoing Cesarean section. Agreement in CO measurements between the two devices was assessed using Bland–Altman plots and the agreement:tolerability index (ATI). Agreement analyses were performed for repeated measures in subjects, using centiles. Results: From 10 women, 307 paired measurements were analyzed. Mean bias (defined as the mean difference in CO measurements between the LiDCOrapid and NICOM devices) was 3.05 (95% CI, 1.89 to 4.21) L/min. Limits of agreement ranged from −1.58 (95% CI, −4.47 to −0.14) to 7.68 (95% CI, 6.24 to 10.56) L/min. The resulting agreement interval was 9.26 L/min which returned an ATI of 2.3. Conclusions: There are large mean differences between CO measurements obtained during Cesarean section using the LiDCOrapid and NICOM hemodynamic monitors inABSTRACT: Objective: Maternal hemodynamics change significantly during Cesarean section complicated by massive hemorrhage or severe hypertensive disease. Cardiac output (CO) monitoring aids early, goal‐directed hemodynamic therapy. The aim of this study was to record hemodynamic changes observed during Cesarean section in pregnancies at high risk of hemodynamic instability, using invasive (LiDCOrapid™) and non‐invasive (NICOM®) devices, and to assess agreement between the two devices in measuring CO. Methods: Simultaneous intraoperative hemodynamic measurements were taken using the LiDCOrapid and NICOM devices, following standardized techniques, in women at high risk of hemodynamic instability undergoing Cesarean section. Agreement in CO measurements between the two devices was assessed using Bland–Altman plots and the agreement:tolerability index (ATI). Agreement analyses were performed for repeated measures in subjects, using centiles. Results: From 10 women, 307 paired measurements were analyzed. Mean bias (defined as the mean difference in CO measurements between the LiDCOrapid and NICOM devices) was 3.05 (95% CI, 1.89 to 4.21) L/min. Limits of agreement ranged from −1.58 (95% CI, −4.47 to −0.14) to 7.68 (95% CI, 6.24 to 10.56) L/min. The resulting agreement interval was 9.26 L/min which returned an ATI of 2.3. Conclusions: There are large mean differences between CO measurements obtained during Cesarean section using the LiDCOrapid and NICOM hemodynamic monitors in pregnant women at high risk of hemodynamic instability, indicating that they should not be considered interchangeable clinically. There is an unacceptably low level of agreement (ATI > 2) in CO measurements between the devices, conferring a high risk of clinical misclassification during massive hemorrhage. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd. … (more)
- Is Part Of:
- Ultrasound in obstetrics & gynecology. Volume 54:Number 2(2019)
- Journal:
- Ultrasound in obstetrics & gynecology
- Issue:
- Volume 54:Number 2(2019)
- Issue Display:
- Volume 54, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 54
- Issue:
- 2
- Issue Sort Value:
- 2019-0054-0002-0000
- Page Start:
- 232
- Page End:
- 238
- Publication Date:
- 2019-07-11
- Subjects:
- cardiac output -- Cesarean section -- hemorrhage -- LiDCOrapid -- NICOM -- non‐invasive monitoring -- pregnancy
Ultrasonics in obstetrics -- Periodicals
Generative organs, Female -- Diseases -- Diagnosis -- Periodicals
Diagnosis, Ultrasonic -- Periodicals
Genital Diseases, Female -- ultrasonography -- Periodicals
Ultrasonography, Prenatal -- Periodicals
618.047543 - Journal URLs:
- http://obgyn.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1469-0705/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/uog.20142 ↗
- Languages:
- English
- ISSNs:
- 0960-7692
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20867.xml