Comparison of different sowtware solutions for AVC quantification using contrast enhanced MDCT. (4th February 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of different sowtware solutions for AVC quantification using contrast enhanced MDCT. (4th February 2022)
- Main Title:
- Comparison of different sowtware solutions for AVC quantification using contrast enhanced MDCT
- Authors:
- Evertz, R
Hub, S
Backhaus, S
Lange, T
Toischer, K
Kowallick, J
Hasenfuss, G
Schuster, A - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Aims: Estimating aortic valve calcification (AVC) derived from multi detector computed tomography (MDCT) scans in aortic stenosis (AS) patients has gained increasing interest for diagnostic and prognostic reasons. Little is known about the interchangeability of AVC obtained from different software solutions which, was systematically determined in consecutive patients undergoing contrast enhanced MDCT before TAVR. Methods and results: 50 randomly selected patients who underwent contrast enhanced MDCT for TAVR planning were included in the analysis. All MDCT data sets were analysed using three different software vendors (3 Mensio, CVI 42, Snygo.Via). AVC score was expressed as mm³. For analysing intra- and inter-observer variability a subset of 10 patients were analysed twice with at least 2 weeks in between the measurements. Intra- and inter-observer variability was quantified using the ICC reliability method, Bland-Altman analysis and coefficients of variation. AVC scores were successfully obtained using all software solutions (3 Mensio 941 ± 623, CVI42 941 ± 637, Syngo.Via 948 mm³ ± 655) without significant differences (p = 0.455). There was excellent intra- (3 Mensio: ICC 0.999 [0.995 – 1.000], COV 3.86 %, mean difference -19.28 [± 45.07]; CVI 42: ICC 1.000 [0.999 – 1.000], COV 1.6 %, mean difference -10.28 [± 18.6]; Syngo.Via: ICC 0.998 [0.993 – 1.000], COV 4.13 %, mean difference -24.81 [± 48.52]) andAbstract: Funding Acknowledgements: Type of funding sources: None. Aims: Estimating aortic valve calcification (AVC) derived from multi detector computed tomography (MDCT) scans in aortic stenosis (AS) patients has gained increasing interest for diagnostic and prognostic reasons. Little is known about the interchangeability of AVC obtained from different software solutions which, was systematically determined in consecutive patients undergoing contrast enhanced MDCT before TAVR. Methods and results: 50 randomly selected patients who underwent contrast enhanced MDCT for TAVR planning were included in the analysis. All MDCT data sets were analysed using three different software vendors (3 Mensio, CVI 42, Snygo.Via). AVC score was expressed as mm³. For analysing intra- and inter-observer variability a subset of 10 patients were analysed twice with at least 2 weeks in between the measurements. Intra- and inter-observer variability was quantified using the ICC reliability method, Bland-Altman analysis and coefficients of variation. AVC scores were successfully obtained using all software solutions (3 Mensio 941 ± 623, CVI42 941 ± 637, Syngo.Via 948 mm³ ± 655) without significant differences (p = 0.455). There was excellent intra- (3 Mensio: ICC 0.999 [0.995 – 1.000], COV 3.86 %, mean difference -19.28 [± 45.07]; CVI 42: ICC 1.000 [0.999 – 1.000], COV 1.6 %, mean difference -10.28 [± 18.6]; Syngo.Via: ICC 0.998 [0.993 – 1.000], COV 4.13 %, mean difference -24.81 [± 48.52]) and inter-observer variability (3 Mensio: ICC 1.000 [0.999 – 1.000], COV 1.38 %, mean difference -7.14 [± 16.20]; CVI 42: ICC 1.000 [1.000 – 1.000], COV 1.01 %, mean difference -1.74 [± 11.83]; Syngo.Via: ICC 0.996 [0.985 – 0.999], COV 6.68 %, mean difference -0.65 [± 79.43]) for all software types. Best inter-vendor agreement was found between CVI 42 and Syngo.Via (ICC 0.997 [CI 0.995-0.998], COV 7.26 %, mean difference -7 [± 68.60]) followed by 3 Mensio / CVI 42 (ICC 0, 996 [CI 0, 922-0, 998], COV 8.95 %, mean difference -0.06 [± 84.16]) and 3 Mensio / Syngo.Via (ICC 0, 992 [CI 0, 986-0, 995], COV 12.19%, mean difference -7.06 [± 115.07]). Conclusion: Contrast enhanced MDCT derived AVC scores are interchangeable between and reproducible within different commercially available software solutions. This is important since sufficient reproducibility, inter-changeability and valid results represent prerequisites for accurate TAVR planning and wide spread clinical use. … (more)
- Is Part Of:
- European heart journal. Volume 23(2022)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 23(2022)Supplement 1
- Issue Display:
- Volume 23, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 1
- Issue Sort Value:
- 2022-0023-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-04
- Subjects:
- Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeab289.359 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20868.xml