Y-Stenting Versus PulseRider-Assisted Coiling in the Treatment of Wide-Neck Bifurcation Aneurysms: Role of Anatomical Features on Midterm Results. Issue 2 (3rd December 2019)
- Record Type:
- Journal Article
- Title:
- Y-Stenting Versus PulseRider-Assisted Coiling in the Treatment of Wide-Neck Bifurcation Aneurysms: Role of Anatomical Features on Midterm Results. Issue 2 (3rd December 2019)
- Main Title:
- Y-Stenting Versus PulseRider-Assisted Coiling in the Treatment of Wide-Neck Bifurcation Aneurysms: Role of Anatomical Features on Midterm Results
- Authors:
- Limbucci, Nicola
Cirelli, Carlo
Valente, Iacopo
Nappini, Sergio
Renieri, Leonardo
Laiso, Antonio
Rosi, Andrea
Amadori, Tommaso
Amadori, Andrea
Mangiafico, Salvatore - Abstract:
- Abstract: BACKGROUND: Y-stenting is an effective but challenging approach for wide-neck aneurysms. PulseRider (PR) (Pulsar/Cerenovus) is a new device designed to provide scaffolding during coiling but has never been compared with other techniques. OBJECTIVE: To compare the immediate and 6-mo results of Y-stenting vs PR assisted coiling. METHODS: A total of 105 consecutive patients were retrospectively divided into 2 groups (73 Y-stenting and 32 PR). All underwent angiographic 6-mo follow-up. We evaluated if some anatomical features could influence treatment results. RESULTS: The groups were homogeneous. Immediate adequate occlusions as well as complication rates were similar in Y-stenting and PR group (94.5% vs 96.9% and 8.2% vs 6.2%, respectively). At 6 mo, adequate occlusion was 93.1% after Y-stenting and 84.3% after PR ( P = .28), complete occlusion was significantly higher after Y-stenting: 90.3% vs 62.5% ( P = .0017). Occlusion grade worsening occurred in 6.9% of Y-stenting and 18.7% of PR patients ( P = .09). Neck size was associated with occlusion grade in both groups. Maximal aneurysm size was associated with occlusion grade in the PR group ( P = .023) but not in the Y-stenting group ( P = .06). After PR, 6-mo occlusion rate was higher in small (< 10 mm) than in large aneurysms ( P = .0094); this was not observed after Y-stenting ( P = .54). Location did not significantly affect the mid-term occlusion rate in both the groups. After PR, occlusion was moreAbstract: BACKGROUND: Y-stenting is an effective but challenging approach for wide-neck aneurysms. PulseRider (PR) (Pulsar/Cerenovus) is a new device designed to provide scaffolding during coiling but has never been compared with other techniques. OBJECTIVE: To compare the immediate and 6-mo results of Y-stenting vs PR assisted coiling. METHODS: A total of 105 consecutive patients were retrospectively divided into 2 groups (73 Y-stenting and 32 PR). All underwent angiographic 6-mo follow-up. We evaluated if some anatomical features could influence treatment results. RESULTS: The groups were homogeneous. Immediate adequate occlusions as well as complication rates were similar in Y-stenting and PR group (94.5% vs 96.9% and 8.2% vs 6.2%, respectively). At 6 mo, adequate occlusion was 93.1% after Y-stenting and 84.3% after PR ( P = .28), complete occlusion was significantly higher after Y-stenting: 90.3% vs 62.5% ( P = .0017). Occlusion grade worsening occurred in 6.9% of Y-stenting and 18.7% of PR patients ( P = .09). Neck size was associated with occlusion grade in both groups. Maximal aneurysm size was associated with occlusion grade in the PR group ( P = .023) but not in the Y-stenting group ( P = .06). After PR, 6-mo occlusion rate was higher in small (< 10 mm) than in large aneurysms ( P = .0094); this was not observed after Y-stenting ( P = .54). Location did not significantly affect the mid-term occlusion rate in both the groups. After PR, occlusion was more stable in basilar than anterior or middle cerebral artery aneurysms. CONCLUSION: Y-stenting and PR are both effective with similar immediate and mid-term results. However, treatment stability seems higher after Y-stenting. Aneurysm size seems to negatively affect PR results. … (more)
- Is Part Of:
- Neurosurgery. Volume 87:Issue 2(2020)
- Journal:
- Neurosurgery
- Issue:
- Volume 87:Issue 2(2020)
- Issue Display:
- Volume 87, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 87
- Issue:
- 2
- Issue Sort Value:
- 2020-0087-0002-0000
- Page Start:
- 329
- Page End:
- 337
- Publication Date:
- 2019-12-03
- Subjects:
- Intracranial aneurysm -- Bifurcation aneurysm -- Stent -- Coiling
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyz490 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20870.xml